System configuration
Setting tools
The areas indicated by the thin lines should be prepared by the customer.
Basic setting items
Basic driving methods
1. Set the necessary parameters from a PC or handy
terminal
2. Set the point data in a similar manner
1. Input a destination point signal from a PLC
2. Input a start signal from a PLC
3. After it is driving, output a “positioning complete” signal from the controller
Name
Quantity
Standard configuration
Actuator unit
1
Controller unit
1
I/O Cable
1
Motor encoder relay cable
1
Configuration (When selecting the set model No.)
Part used
Model No.
Manufacturer
Surge protector
R/A/V-781BXZ-4
R/A/
V-781BWZ-4
RSPD-250-Q4
RSPD-250-U4
OKAYA ELECTRIC
INDUSTRIES CO.,
LTD.
A surge protector is required to comply with the CE marking. Refer
to the Instruction Manual for details about installation and wiring.
We offer the "ETP2" handy terminal.
We offer the "E Tools" electric actuator setting software.
(Windows version provided free of charge)
You can set the point data and parameters for the ERL2/ESD2
electric actuators and issue operation instructions from a PC.
The point data and parameter data can be saved to the PC.
An RS-485 interface and a PC communication cable
(EC-CBLPC1) are required for a PC connection.
Recommended RS-485 interface model numbers
MISUMI PCCM-COM-1PDUSBH-R
CONTEC COM-1PD (USB) H
Note 1: Because the PC communication cable is designed
specifically for CKD's electric actuator, commercially
available communication cables cannot be used.
Accidentally using the wrong cable may damage the
controller and PC.
Note 2: The handy terminal and PC are expected to only be
connected when making adjustments. Remove the cable
from the controller during normal operation.
Note 3: The PC may be unable to recognize the RS485 interface
when recovering from sleep mode, and communication
anomalies may occur.
Actuator
ERL2 Series
Refer to pages 1 to 11
Actuator
ESD2 Series
Refer to pages 13 to 27
PLC
Handy terminal
ETP2
Refer to pages 39 to 40
(Sold separately)
PC communication cable (sold separately)
EC-CBLPC1
Refer to page 41
PC
Motor encoder relay cable
(Fixed, movable) Refer to page 42
I/O Cable
Refer to page 42
Controlle
EC07/EC63/ECPT
Refer to pages 29 to 38
24 VDC
power supply
Power supply
Noise filter
(Sold separately)
Refer to page 41
Ground
Ground
Surge protector
(Sold separately)
Refer to page 41
RS485 interface
Ground
Ground
Ground
Intro 1
Содержание ERL 2-45
Страница 1: ...Space saving installation Flexible motor mounting...
Страница 43: ...ME M O MEMO 36...
Страница 51: ...ME M O MEMO 44...