6. Device Configuration

7.Group Device

6.2.2 Configuration

To configure a new CG100 device, perform following steps.
1 - Power up the new CG100 device.
2 - Connect the Wireless remote controller 
     (which is used to configure the Coordinator 
     before) to the new device through the 
     provided cable.
3 - Press the navigation button to enter Menu, 
     then select "Dev. Manager" and go to 
     "Config Device".
4 - Press "Yes" button to configure the new 
     device.
     (Note: The icon     is indicating the new 
      device is trying to connect to the network).
5 - If the device is configured successfully, the 
     wireless remote controller will show "Config 
    Device Success".
     During the configuration of new device, 
     if "Fail" or "Device Not Found" is shown by 
     wireless remote controller, please check the 
     power of the new device and the connection 
     between the new device and wireless 
     remote controller. Then perform step 1 to 
     step 4 again. 

Repeat steps stated in Section 6.2.1 and Section 6.2.2 to install the rest 
of the devices

7.Group Device

6. Device Configuration

6.3 Wireless Remote Controller

During the configuration of coordinator, the wireless remote controller will be self-configured 
automatically. User may use such wireless remote controller to configure other new device in 
the network. On the other hand, when there are more than one wireless remote controller 
within the system, user shall configure the other wireless remote controller (which are not used 
to configure coordinator) manually before using the wireless remote controller. To configure 
the handheld remote manually, perform following steps.

1 -Connect the new wireless remote controller to any 
    successful configured CG100 Coordinator/device 
    through the provided cable.
2 -Press the navigation button to enter Menu, then 
    select "Dev. Manager" and go to "Config Remote".
3 -Press "Yes" button to configure the wireless remote
    controller.
4 -When the wireless remote controller is configured 
     successfully, the wireless remote controller will show 
    "Config Remote Success'.
During the configuration of wireless remote controller, 
if "Fail" or "Device Not Found" is shown by the wireless 
remote controller, please check the power of the 
Coordinator/device and the connection between the 
Coordinator/device and wireless remote controller. Then 
perform step 1 to step 3 again

After the CG100 devices are installed and configured, user may assign a corresponding 
button (1-10) on Wireless remote controller to control one or more devices (maximum three), 
which is called group control. The procedures of adding device to a group and controlling 
grouped devices are illustrated in Section 7.1 and Section 7.2 - 7.3 respectively.

 

7.1

 Add Device to Group

To add device to group control, perform following steps.
1 -Connect the Wireless remote controller 
    (which is configured before) to the desired device 
    (eg. One-gang Switch, Two-gang Switch, Dimmer 
     Switch, Socket, etc.) through the provided cable.
2 -Press the "Navigation"  button to enter Menu, then 
    select "Group Config".
    (Note: All the groups will show on the screen, user 
     may scroll to view the groups.)
    (Note: If there is/are device(s) added to the group, 
     the Wireless remote controller will show the name of the 
     group. eg. The default group name of the first 
     group is "Group 1".)
    (Note: If there is no device added to the group, the 
     Handheld will show "(Empty)".)
3 -Press "Yes" button to select the desired group.
    (Note: If there is no device added to the group, the 
     Handheld remote will show "No Device".)
    (Note: If there is/are device(s) added to the group, 
     the Wireless remote controller will show the name of the 
     device.)
4 -Scroll down to find "Add Device"
    (Note: If there are three devices already added to 
     the group, the "Add Device" function will be 
     disabled and user may not found such function 
     within the group.)
5 -Press "Yes" button to add device
    The Wireless remote controller will show 
    "Press Desired Device", and the status LED of 
    connected device will keep flashing.
6 -Press the desired device control button on the 
    device to add the device to the group. 
 

For example, when the Wireless remote controller is 
connecting with the Two-gang Switch and user press 
the second button of the switch, the device control 
function of the second button of the switch will be 
added to the group.

7 -When the device is added to the group successfully, 
the Wireless remote controller will show "Add Device Success"
If "Fail" or "Device Not Found" is shown on the Wireless 
remote controller during the above process, please check  the 
power of the Coordinator/device and the connection 
between the Coordinator/device and Wireless remote controller. 
And you can also check the memory information of 
Wireless remote controller(see Section 9.4). Then perform 
step 1 to step 6 again.

7.2 On/OFF Control

After the devices are added to different groups, user may control the group of device(s) 
through a single button (1 - 10 buttons) on the Wireless remote controller.

Important: Please ensure the wireless remote controller is within the system coverage 
before controlling any device.

Following examples show the procedures to control a group of device.
Press and hold the "Back" button to exit the menu and show the device status page. 

From the above example of device status page:
                       Group 1:  Device(s) is/are HALF ON
                       Group 2:  No device in Group 2
                       Group 3:  Device(s) is/are ON
                       Group 4:  Device(s) is/are OFF
                       Group 5:  Device(s) is/are OFF

 

Содержание CG100R

Страница 1: ...select the right location for your light switch dimmer and AC socket It should be 1 Easily accessible for programming and other operations 2 In a location away from water humidity direct sunlight and...

Страница 2: ...01AS CG201AS 2 INTRODUCTION 2 INTRODUCTION Thank you for selecting product this intelligent Home Automation system is working on IEEE 802 15 4 Communication standard It offers beneficial features like...

Страница 3: ...t controlprocess Device Status Page Up All ON Device Status Page Edit Name Press Press Turn ON allthe devices Backspace 3 2 LCD DisplayIcons System Clock Not Set Operation of navigationbutton up anddo...

Страница 4: ...s at the rear cabinet of the devices Then connect the load cable to the Load terminals One gang Two gang lightswitch Or dimmer AC socket d Fasten the screws of all terminals and check that the wires a...

Страница 5: ...rformance user is strongly advised to test the system coverage of the location that is planned to install the CG100 devices On the other hand when a CG100 device is configured successfully the system...

Страница 6: ...d devices are illustrated in Section 7 1 and Section 7 2 7 3 respectively 7 1 Add Device to Group To add device to group control perform following steps 1 Connect the Wireless remote controller which...

Страница 7: ...reless remote controller the Wireless remote controller will turn OFF all the devices in group 9 After all the devices in group 9 are OFF the status of devices will feedback to Wireless remote control...

Страница 8: ...enselect Edit Name 3 Press Yes button toedit the nameof selected device Left Right buttons Changethe position of cursor ALL OFF button Change the case a A 1 ALL ON button Backspace Yes button Save the...

Страница 9: ...control Press and hold the Back button to exit the menu and show the device status page Press Yes Mood button to enter mood control page Press button 1 5 to select the desired mood After all the devi...

Страница 10: ...mood 2 Press Yes button toenter the deviceoption menu and thenselect ShowAddress 3 Press Yes button againshow the uniqueaddress of the device 8 6 3 Edit DeviceName Toedit the devicename of devicein m...

Страница 11: ...ler There are someexamples When user addedthe load ofa one gang switchto group 1of the Handheldremote controller the number ofregistered device is1 When user addedthe load ofone gang switch togroup3 m...

Страница 12: ...is disabled For example when the timersetting of a lightswitch is Light SW 1ON Light SW 1OFF 12 02 Which means theON timer ofthe light switchis disabled and thelight switch willonly turn OFF at 12 02...

Страница 13: ...vice but want to configureas N Way controller Whether thedevice is aN Way controller but want to configureas N Way device The powerof the devices The cableconnection between thedevice and Wireless rem...

Страница 14: ...201C CG201S1 CG201S2 CG201SK Dimmer Voltage 220 to 240Vac Maximum Load Communication standard Bi directional control Radio Frequency Operating Temperature Operating Humidity Mounting Centers 10Amp 250...