CityGrow CG100R Скачать руководство пользователя страница 11

41

40

9.  System Setting

9.  System Setting

9.  System Setting

9.  System Setting

42

43

9.2 Copy Setting

You are able to copy the setting of Wireless remote controller to another Wireless 
remote controller through the provided cable. To copy the setting, perform follow steps:

1- Connect the source Wireless remote controller to a
     destination Wireless remote controller through he 
     provided cable.
2-  Press the "Navigation" button to enter Menu, 
     and then select "Setting"      "Copy Setting" on 
     the source Wireless remote controller.
3-  Press any button on destination Wireless 
     remote controller to wake up the remote.
4-  Press "Yes" button on the source Wireless 
     remote controller to prepare to copy setting.
     The destination Wireless remote controller will ask 
     user to accept the setting.
5-  Press "Yes" button on the destination 
     Wireless remote controller to accept the setting.
6-  After the setting is copied successfully, 
     both the source and destination Wireless remote 
     controller will show "Copy Setting Completed"

9.3 Reset

User may reset the Handheld remote to factory default setting and 

all the setting of 

the Wireless remote controller will be deleted.

To reset the Wireless remote controller, perform 
following steps.
1-  Press the "Navigation" button to enter Menu, 
     then select "Setting"      "Reset"
2-  Press "Yes" button to start reset the Wireless
     remote controller.
     The Wireless remote controller will show the 
     warning message "Reset will del all setting" and 
     then ask user to confirm.
3-  If the user confirmes to delete all the 
     setting, press "Yes" button again to reset the 
     Wireless remote controller. Otherwise, press 
     "Back" button to cancel the reset.
4-  After finishing reset process, the Wireless 
     remote controller will show "Reset Success".

9.4 Memory Information

User may inquire the memory information of the Wireless remote controller from the 
setting menu ("Setting"      "Memory info" ).
There are two types of memory information showing for the user-------- the" Registered
 Device" and "Device Added to Gps and Moods".

9.4.1  Registered Device

The Wireless remote controller can register maximum 50 devices to the memory for 
group or mood control. The number of device is referring to the number of

 “

device loads

 

added to the Wireless remote controller.

There are some examples:
When user added the load of a one-gang switch to group 1 of the Handheld remote 
controller,
      

 the number of registered device is 1.

When user added the load of one-gang switch to group3, mood 1 and mood 2 
of the Wireless remote controller, 
       

the number of registered device is also 1.

When user added the  "load 1" and "load 2" of a two-gang switch to group 1 of the
Wireless  remote controller, 
      

 the number of registered device is 2.

When user added the "load 1" of a two-gang switch to group 1 and "load 2" of the same
 two-gang switch to group 3 of the Wireless remote controller.
       

the number registered device is 2.

When user added the load of a socket to group 1 of the Wireless remote controller
       

the number of registered device is 1.

When user added the load of dimmer switch to group 1 of the Wireless remote controller
       

the number of registered device is 1.

9.4.2 Device Added to GPs and Moods

The Wireless remote controller can be added with
maximum 200 device records to the 
memory for group or mood control.

There are some examples:
   When user added the load of a one-gang switch to group 1of the Wireless remote
   controller,
      

 the number of registered device is 1.

       the number of device added to Gps and Moods is 1

   When user added the load of a one-gang switch to group 1, group 3, mood 1 and 
   mood 2 of the Wireless remote controller,
       

the number of registered device is 1.

       the number of device added to Gps and Moods is 4.

   When user added the both "load 1" and load2" of a two-gang switch to group 1 of the 
   Wireless remote controller,
      

 the number of registered device is 2.

       the number of of device added to Gps and Moods is 2.

   When user added the "load 1" of a two-gang switch to group 1 and "load 2" of the 
   same two gang switch to group 3 of the Wireless remote controller,
      

 the number of registered device is 2.

       the number of device added to Gps and Moods is 2.

   When user added the load of a socket to group 1 of the Wireless remote controller,
       

the number of registered device is 1.

       the number of device added to Gps and Moods is 1.

   When user added the load of a dimmer switch to group of the Wireless remote
   controller,
      

 the number of registered device is 1.

       the number of of device added to Gps and Moods is 1

   When user added the load of a socket to all the groups (group 1 to group 10) and all 
   the moods (mood 1 to mood 5) of the Wireless remote controller.
      

 the number of registered device is 1.

       the number of of device added to Gps and Moods is 15.

Содержание CG100R

Страница 1: ...select the right location for your light switch dimmer and AC socket It should be 1 Easily accessible for programming and other operations 2 In a location away from water humidity direct sunlight and...

Страница 2: ...01AS CG201AS 2 INTRODUCTION 2 INTRODUCTION Thank you for selecting product this intelligent Home Automation system is working on IEEE 802 15 4 Communication standard It offers beneficial features like...

Страница 3: ...t controlprocess Device Status Page Up All ON Device Status Page Edit Name Press Press Turn ON allthe devices Backspace 3 2 LCD DisplayIcons System Clock Not Set Operation of navigationbutton up anddo...

Страница 4: ...s at the rear cabinet of the devices Then connect the load cable to the Load terminals One gang Two gang lightswitch Or dimmer AC socket d Fasten the screws of all terminals and check that the wires a...

Страница 5: ...rformance user is strongly advised to test the system coverage of the location that is planned to install the CG100 devices On the other hand when a CG100 device is configured successfully the system...

Страница 6: ...d devices are illustrated in Section 7 1 and Section 7 2 7 3 respectively 7 1 Add Device to Group To add device to group control perform following steps 1 Connect the Wireless remote controller which...

Страница 7: ...reless remote controller the Wireless remote controller will turn OFF all the devices in group 9 After all the devices in group 9 are OFF the status of devices will feedback to Wireless remote control...

Страница 8: ...enselect Edit Name 3 Press Yes button toedit the nameof selected device Left Right buttons Changethe position of cursor ALL OFF button Change the case a A 1 ALL ON button Backspace Yes button Save the...

Страница 9: ...control Press and hold the Back button to exit the menu and show the device status page Press Yes Mood button to enter mood control page Press button 1 5 to select the desired mood After all the devi...

Страница 10: ...mood 2 Press Yes button toenter the deviceoption menu and thenselect ShowAddress 3 Press Yes button againshow the uniqueaddress of the device 8 6 3 Edit DeviceName Toedit the devicename of devicein m...

Страница 11: ...ler There are someexamples When user addedthe load ofa one gang switchto group 1of the Handheldremote controller the number ofregistered device is1 When user addedthe load ofone gang switch togroup3 m...

Страница 12: ...is disabled For example when the timersetting of a lightswitch is Light SW 1ON Light SW 1OFF 12 02 Which means theON timer ofthe light switchis disabled and thelight switch willonly turn OFF at 12 02...

Страница 13: ...vice but want to configureas N Way controller Whether thedevice is aN Way controller but want to configureas N Way device The powerof the devices The cableconnection between thedevice and Wireless rem...

Страница 14: ...201C CG201S1 CG201S2 CG201SK Dimmer Voltage 220 to 240Vac Maximum Load Communication standard Bi directional control Radio Frequency Operating Temperature Operating Humidity Mounting Centers 10Amp 250...

Отзывы: