![CityGrow Systems CG400 Series Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/citygrow-systems/cg400-series/cg400-series_user-manual_2611511026.webp)
23
Specifications - Loads
CG400SW
CG400DM
CG400FL
CG400S2-CCP
Description
One-Gang Switch
Module
One-Gang Dimmer
Module
Two-Gang Dimmer
Module
One-Gang Curtain
Control Switch Module
Resistive load (Per Gang)
1.
Incandescent
2.
Halogen
3.
Electronic low voltage – ELV
transformer
1000W
400W
N/A
N/A
Inductive load (Per Gang)
1.
Magnetic low voltage – MLV
transformer.
2.
Iron core / Inductive
transformer
1000VA
400VA
N/A
N/A
Fluorescent (Per Gang)
700W
N/A
700W
25mA max. for
1-10V DC output
Max. 24pcs 1-10V
dimming interface
N/A
Compact fluorescent - CFL (Per
Gang)
400W
Max. 24 pcs
CFL**
250W
Dimmable CFL
Max. 20 pcs
CFL**
N/A
N/A
LED – GU10 (Per Gang)
200W
40W
N/A
N/A
LED – MR16, MR11 (Per Gang)
With electronic low voltage LED
driver
400W
Max. 10 pcs
ELV LED driver*
80W
Max. 15 pcs
ELV LED driver*
400W
25mA max. for
1-10V DC output
Max. 24pcs 1-10V LED
dimming interface
N/A
LED strip (Per Gang)
With electronic low voltage
driver
400W
Max. 10 pcs
ELV LED driver*
N/A
400W
25mA max. for
1-10V DC output
Max. 24pcs 1-10V LED
dimming interface
N/A
Exhaust fan (Per Gang)
300VA
N/A
N/A
N/A
3 wire type AC curtain motor
N/A
N/A
N/A
300VA
Minimum load
5W
**Remarks:
1.
The maximum load requirements for fluorescent, CFL and LED loads can vary greatly depending upon the
specific fixture and /or bulb being used.
Содержание CG400 Series
Страница 16: ...13 4 1 CG400SW CG400DM Distribution Panel Live Neutral Neutral Load Load L N OUTPUT N L INPUT...
Страница 17: ...14 4 2 CG400FL Distribution Panel Live Neutral Neutral Load Load L N OUTPUT N L INPUT Driver DC DC...
Страница 18: ...15 4 3 CG400S2 CCP Distribution Panel Live Neutral Neutral L1 Load L1 L2 OUTPUT N L INPUT L2...