17
STEP 4:
Connect the main power cable to the Live and Neutral terminals. Connect the load
cable to the Load terminals at the back cabinet of the product.
L N
OUTPUT
N L
INPUT
Live from MCB
Neutral from MCB
Neutral to Load
Output to Load
*** For CG400FL, connect 1-10V DC dimming voltage output to the corresponding
input of the lamp/ lamp driver. See following diagram
- 0-10VDC +
25mA OUTPUT