6.
Programming the travelling time of the motorized curtain
The default travelling time of the CG400S2-CCP is 20 seconds. User may use the TEST button
to re-program the travelling time. Please refer to the following instructions.
Open
Stop
Close
Stop
Press
P
re
s
s
Press
P
re
s
s
Follow the below procedures to program travel time of CG400S2CCP:
1.
Press the TEST button until the curtain is fully closed.
You may have to press the button for several times in a sequence of “Open
Stop
Close (20 second and stop automatically)
Open
Stop
Close (20 second and stop
automatically) to fully close the curtain.
2.
When the curtain is fully closed, press and HOLD the TEST button until the curtain is
starting to open.
3.
When the curtain is opening, release the TEST button.
4.
When the curtain is fully opened, press and release the TEST button to complete the
programming of the travelling time.