Attach the Mounting Bracket Base to a pipe using a stainless steel hose clamp as shown: 
 

 

Slide the mating Mounting Bracket (attached to the Unit) into the Mounting Bracket Base until 
the locking clip engages, and install the retaining screw. 
  

Cable or Conduit Entry 

The unit enclosure is provided with ½” NPT entry holes fitted with liquid-tight cable grips for 
use with outdoor use cables (by installer) for power, DMX, and Ethernet connection.    
The recommended torque for these cable grips is as follows: 
 

Locking

 

Nut

 

40

45

 

inch

 

pounds

 

Sealing

 

Nut

 

50

55

 

inch

 

pounds

 

 

If outdoor use conduit is used instead, it is recommended that the conduit be sealed after 
installation to prevent moisture entry, including free air exchange, in order to minimize the 
chance of condensation buildup. 
 

Page 

3 of 7 

 
 
 

Содержание 7400-5708 Vero Net

Страница 1: ... all assembled equipment functions safely and properly Important use notes This unit must be used with voltages below 600V This unit must be installed in accordance with the National Electrical Code ANSI NFPA 70 where the ambient temperature does not exceed 40 C 104 F maximum Grounding This enclosure has been provided with a ground bond jumper for ground connection between the back box and the cov...

Страница 2: ...Button Head Security Screw in the hole on the left side of the Bracket assembly Page 2 of 7 Mounting Orientation The 7400 5708 SHoW DMX Vero Net Transceiver must be mounted exclusively in an upright mounting position with the cable entries on the bottom and antenna connector on the top as shown in the drawing above Pipe Mounting The SHoW DMX Vero can also be mounted on a pipe ...

Страница 3: ...ded with NPT entry holes fitted with liquid tight cable grips for use with outdoor use cables by installer for power DMX and Ethernet connection The recommended torque for these cable grips is as follows Locking Nut 40 45 inch pounds Sealing Nut 50 55 inch pounds If outdoor use conduit is used instead it is recommended that the conduit be sealed after installation to prevent moisture entry includi...

Страница 4: ...onnection is a 3 pos plug socket type terminal block which may be disconnected for ease of assembly Strip insulation from individual conductors 25 7mm and terminate in the provided screw terminal socket see illustration above Mains terminations are ash shown and are marked on the unit DMX512 Wire Termination The SHoW DMX Vero Net Transceiver is provided with a PCBA mount terminal block for DMX con...

Страница 5: ...et Transceiver has a two part cover with the outer plastic cover connected to the inner metal cover with a hinge Install the metal inner cover using the ei the screw threads are fully engaged with the mating PEM Nut then tighten to 4 inch pounds The outer cover is then closed and secured with the provided 8 18 x 500 SS Thread Forming orx Button Head Security Screw installed in the provided hole on...

Страница 6: ...lid onfirm the In Range LED on all receivers is lit ration switches P5 DMX Term DMX c P4 Rx Tx o P P2 Bootloader On or Off Sets the unit to Bootloader mode to upload a P1 Default On or Off To res 1 Set P1 Default to On 2 Wait for PCBA LE QUICK SETUP For a basic 7400 5708 SHoW DMX Vero Net System you will need one 7400 5708 SHoW DMX Vero Net Tran use as a receiver 1 Install the Vero Net units as sh...

Страница 7: ...presents a combination of one of 16 hopping patterns and one of four bandwidth settings 7400 5708 Vero Transceiver supports SHoW DMX Classic Neo and Neo Adaptive SHoW IDs The Transmitter and Receiver SHoW IDs must match for the units to communicate See the 7400 5708 SHoW DMX Vero Net Users Manual for more details about other system setting options The Users Manual and the SHoW DMX Neo Installation...

Отзывы: