- 118 -
fn = 3, 51: Function 3 Specifies the auto loading function of the set value at
initialization to be valid or invalid
GS ( M pL pH fn m
[Code]
<
1D
>
H
<
28
>
H
<
4D
>
H
<
pL
><
pH
><
fn
><
m
>
[Range]
(
pL
+
pH×256
)=
2
(
pL
=
2
、
pH
=
0
)
fn=
3
、
51
m
=
0
、
1
、
48
、
49
[Outline]
Determines the setting of storage area at initialization to the work area by the value of
“m”.
m Function
0,48
Does not copy data from storage area to work area at initialization.
1,49
Copies data from storage area to work area at initialization.