- 113 -
GS ( K pL pH fn m
[Function]
Selecting print control method
[Outline]
Executes the setting related to the print control specified by the value of “fn”.
Function No. (fn)
Function
Function 48
Sets print control mode.
Function 49
Sets printing density.
Function 50
Sets printing speed.
Function 97
Sets the number of divisions for head conducting.
fn = 48: Function 48 Setting Print Control Mode
GS ( K pL pH fn m
[Code]
<
1D
>
H
<
28
>
H
<
4B
>
H
<
pL
><
pH
><
fn
><
m
>
[Range]
(
pL
+
pH×256
)=
2
(
pL
=
2
、
pH
=
0
)
fn=
48
0
≦
m
≦
4
、
48
≦
m
≦
52
[Outline]
Sets print control mode.
m
Print Control Mode
0,48
Selects the print control mode at power on.
1,49
Sets print control mode 1 (standard)
2,50
Selects the print control mode at power on.
3,51
Selects the print control mode at power on.
4,52
Selects the print control mode at power on.
[Default]
m
=
1