Citizen Eco Drive B740 Скачать руководство пользователя страница 2

1. OUTLINE 

This watch is an analog solar powered diver's watch into which an electronic 
depth meter and chronograph function and chronograph function are built. The 
solar power generation function transforms solar energy into electrical energy 
to run the watch. 
• Since solar energy is used as the power source of this watch, it has no need 

of regular replacement of the battery unlike the general diver's watches 
using the mercury cell, etc. (Solar power function) 

• The built-in depth meter function automatically measures the depth in diving 

with the watch worn on the wrist. (Depth meter function) 

• The maximum depth in diving is automatically memorized. (Maximum depth 

memorizing function) 

• The chronograph function measures the time in units of one second for 

50

minutes at maximum. 

2. SPECIFICATIONS 

Movement Caliber NO.

Type

Watch Accuracy (At normal 
temperature)

Depth gauge accuracy 

Operating temperature 

Time

Calendar

Display
functions

Chronograph

Depth gauge 

Maximum depth to be 
memorized

Additional functions 

Continuous

operating time 

Additional
Comments

B740M / B741 M 

Analog solar power watch 

±15 sec/month (5'C-35OC/41"F-95"F) 

At depth of 1 to 1 Om/5.0 to 25.Oft: within ± 1 
m/±5.Oft
At depth of 1 to 1 to 50m/27.5 to 125.Oft: within 
±2m/±7.5ft
On the condition that the water temperature is 
constant and error in reading is excluded. 
Temperature range for guaranteed accuracy: +10'C to 

40'C/50'F to 104OF 

Depth gauge accuracy is influenced by changes in 
surrounding temperature. 

-1OC to +60OC/14F to 40F 

Hour, Minute, Second, 24-hour, Charge level 

Date

Minute, Second (50-minute system) 

1 m to 50m/5ft to 1 25ft 

Reading in units of lm/5ft 

Depth less than 1 m/5ft is indicated as 0m/Oft. 
Depth more than 50m/1 25ft is indicated as over-zone 

1 m to 50m/5ft to 1 25ft 

*

 Charge level indication function 

*

 Insufficient charge warning indication a Stop 

warning function 

*

 Time reset warning function 

*

 From full charge to stopping: Approx. 2 months 

*

 From full charge to 

NG

indication: Approx. 1 month 

*

 Form insufficient charge warning to stopping: Approx. 

2 days 

Movement Caliber B740: Depth indication in meters 
Movement Caliber B741: Depth indication in feet 

Return to Table of Contents

Return to Table of Contents

Содержание Eco Drive B740

Страница 1: ...Care for This Solar Powered Watch e Switching Between Modes f Adjusting the Time and Date Time Mode g Diving Mode h Chronograph Mode i Measure Against Possible Problems j Setting Function Hand at 0 Po...

Страница 2: ...tional functions Continuous operating time Additional Comments B740M B741 M Analog solar power watch 15 sec month 5 C 35OC 41 F 95 F At depth of 1 to 1 Om 5 0 to 25 Oft within 1 m 5 Oft At depth of 1...

Страница 3: ...atch will continue running for about two months 4 USING THIS WATCH A Name of Parts Charge level of the battery battery power is indicated as follows LV 1 LV 2 NG by the function hand These guidelines...

Страница 4: ...he charging level which is indicated by the function hand When the function hand points at LV 2 54 seconds The battery is almost fully charged Accordingly the watch can be used reliably for diving Whe...

Страница 5: ...for Charging Insufficient charge warning indication Made hand DV position Function hand NG position Whenever the battery power becomes insufficient for operation the watch is automatically shifted to...

Страница 6: ...ondition the second hand moves irregularly every two seconds to show that the time is incorrect Time reset warning indication This watch has an overcharge prevention function When the secondary batter...

Страница 7: ...state that the watch has stopped operation in the stop warning indication Charging time for one day operation Time required for charging the battery enough for running the watch for one day starting...

Страница 8: ...e battery only Never use any battery other than the specified rechargeable battery This watch is so designed that it does not run with any battery other than the specified secondary battery However if...

Страница 9: ...e levels Note on operation of the crown x The crown of this watch is designed to be screwed down onto the case to secure the water resistance of the watch x For pulling out the crown for adjustment un...

Страница 10: ...depth When the depth is less than 1 m 5 ft the function hand indicates 0 m 0 ft When the depth exceeds 50 m 1 25 ft the function hand stops at the over zone mark 52 seconds position to show that the...

Страница 11: ...suring time and the hands move to the reset position Chronograph indication Reset position If the watch is left in reset status in the chronograph mode for 3 minutes it automatically switches to the T...

Страница 12: ...the user is at high altitudes or is on an airplane flight the watch may unexpectedly be shifted to the Diving mode because of a sharp change in the atmospheric pressure pressure change equivalent to t...

Страница 13: ...on and turn it until it is tightly screwed against the case x If the watch has been left without any operation for 3 minutes or longer as the crown is pulled to the second click stop position the func...

Страница 14: ...dicated for about one month in which the watch can be used for diving If the battery is fully charged function hand indicates LV 2 In several hours one day after charging is stopped the scale indicate...

Страница 15: ...fety and assuming the worst condition 6 NOTE ON ECO DRIVE RECHARGEABLE BATTERY Be sure you fully understand the precautions on use of this watch and how to use it in advance Before using this watch fo...

Страница 16: ...m 60 ft Before diving with this watch fully charge the battery without fail When the battery is not sufficiently charged the function hand points at NG the depth meter function cannot be used If batt...

Страница 17: ...f the watch Example 20 m 65 ft indicated depth x 1 025 20 5 m 67 ft real depth When the watch is shifted to the dive mode the pressure sensor regards the ambient pressures as that on the sea level 0m...

Страница 18: ...sed container It should be dried immediately or taken to a watchmaker or jeweler if moisture is inside the case to prevent damage from rust Vital components necessary to resist the entrance of moistur...

Страница 19: ...ct with moisture If your model is equipped with a screw down crown be sure it is properly seated against the case Do not operate the crown or any push button when the watch is wet as this may allow th...

Страница 20: ...ute position To review the depth of the last dive while in the time mode press and release the upper right button to activate the call feature The function hand will rotate to indicate the depth attai...