CBM-270 User’s Manual
CITIZEN
86
GS C2 n1 n2
[Function]
Setting the numbering counter
[Code]
<1D>H<43>H<3B>H<N1><3B>H<N2><3B>H<N3><3B>H<N4><3B>H
<N5><3B>H
<1D>H<43>H<32>H<n1><n2>
[Range]
0
£
n1
£
255, 0
£
n2
£
255
[Outline]
This command sets the numbering (serial number counter) value.
n1 + n2
´
256 (n1 = remainder, n2 = quotient) becomes a counter value.
[Caution]
If the counter is set with this command, a repeat count of the identical counter
will be cleared. If the counter value is beyond the Range specified with the "GS
C1" or "GS C;" command, the counter will be initialized.
[Default]
Not defined.
[See Also]
GS C0, GS C1, GS c, GS C ;
[Sample Program]
[Print Result]
See the sample program and print result for the GS C1 command on Page 82.
GS C; N1; N2; N3; N4; N5;
[Function]
Setting the numbering counter mode (B)
[Code]
<1D>H<43>H<3B>H<N1><3B>H<N2><3B>H<N3><3B>H<N4><3B>H
<N5><3B>H
<N1>, <N2>, <N3>, <N4>, and <N5> are character codes.
[Range]
0
£
N1, N2, N5
£
65535 0
£
N3, N4
£
255
[Outline]
This command sets the numbering (serial number counter) mode and a counter
value.
N1
: Counter default
N2
: Counter final value
N3
: Counter step value
N4
: Identical counter print count
N5
: Counter start value
N1<N2
: Count-up system
N1>N2
: Count-down system
N1 = N2
or
N3 = 0
: Counter stop
or
N4 = 0
Содержание CBM-270
Страница 50: ...CBM 270 User s Manual CITIZEN 50 ...
Страница 94: ...CBM 270 User s Manual CITIZEN 94 German ...