background image

4. Description of the A/C AIR LAUNCHER

TM

 

The user has the ability to produce a spectacular simulated fireworks display, outdoors, 
without the risk of fire!  When loaded properly, this device will safely propel tissue 
streamers and/or tissue (not paper) confetti to distances of up to 100’ in the air!  The end 
result resembles a cascading display of daytime firework-like effects.  Note:  due to wind 
resistance and low weight, confetti will not travel as far as streamers.  The included 7-
gallon air tank must be filled from an air compressor or be connected into a constant 
replenishing CO

2

 air cylinder tank (available from your local gas supplier), eliminating the 

need for manual refills. The CO

2

 air tank makes it economically feasible to do continuous 

reloads and refills for places like circuses or theme parks. The A/C Air Launcher™ 
features a built-in safety release, two types of filling valves, a pressure gauge, and an 
electric release solenoid valve (1/2" high-volume type).  The launcher fires as soon as it 
is plugged in, or if connected to an electrical switchbox, as soon as it is switched on. 
Launcher comes with a 24VAC solenoid valve and 120VAC/240VAC, 24V transformer. 
 

 

5.

 

Safety instructions 

 

WARNING: Read and understand all labels and operating instructions 

before attempting installation. 

 

o

 

Inspect all equipment and barrel before use. Do not use if barrel is cracked or chipped. 

o

 

Be sure area around launcher is dry before applying electrical power. 

o

 

Never point the muzzle directly at anyone or look over the barrel when pressurized and 
loaded.  

o

 

Secure the launcher so that it will not be moved after it is aimed. 

o

 

Use a safety cable if the launcher is rigged above ground. 

o

 

When using, keep away from spectators and always aim straight up over everyone’s 
head 

o

 

WARNING!  Never use a confetti-launching product if there are open flames present. 

o

 

Use only tissue-type confetti or streamers that are flame retardant as sold by CITC.  

o

 

Never use paper dots or heavy paper confetti. 

o

 

Pressurize up to maximum 100 PSI (6.9 bar) only! 

 

Содержание A/C Air Launcher 101050

Страница 1: ...A C AIR LAUNCHERTM Operating Instructions P N 101050 120 VAC P N 101051 230 VAC ...

Страница 2: ...new product is quite extensive To guarantee perfect and successful work with this machine please take some time to read the manual carefully And finally we believe you will enjoy years of great effects if you care for and maintain your A C AIR LAUNCHERTM CITC 1420 80TH SW D EVERETT WA 98203 888 786 CITC www citcfx com ...

Страница 3: ...4 Description 4 5 Safety Instructions 4 6 Operating the A C AIR LAUNCHERTM 5 6 1 Assembly 6 2 Loading 6 3 Optional backpressure cap 6 4 Pressurizing the tank 6 5 Firing the A C Air LauncherTM 6 6 Troubleshooting 7 Service and Maintenance 7 8 Technical Data 7 9 Limited Warranty Conditions 8 ...

Страница 4: ...tock Custom mix by request Tissue Confetti Multicolor or solid colors 5 8 x 2 1 4 1 6cm x 5 7cm P N 255501 Mylar Tissue Confetti Silver or gold Mylar color tissue 5 8 x 2 1 4 1 6cm x 5 7cm P N 255651 STREAMERS SPEED LOAD FlameProof Biodegradeable Tissue Paper Mylar 1 x 20 2 5cm x 51cm soft sleeve for quick loading of your cannons slide in then remove sleeve no packing Tissue Streamer 1 2 x 30 1 3c...

Страница 5: ...an electric release solenoid valve 1 2 high volume type The launcher fires as soon as it is plugged in or if connected to an electrical switchbox as soon as it is switched on Launcher comes with a 24VAC solenoid valve and 120VAC 240VAC 24V transformer 5 Safety instructions WARNING Read and understand all labels and operating instructions before attempting installation o Inspect all equipment and b...

Страница 6: ...streamers The more you include the more spectacular the effect If your budget allows using 120 rolls looks great If you want an unbelievable effect use 240 rolls You may fill the unit to the top if you wish or just load it to full Outdoors or large arenas the bigger and heavier streamers will travel further For the highest altitude and the best visual effect load at least 36 of the 30 streamers Wa...

Страница 7: ...ns This unit is equipped with a 120VAC 240VAC 24VAC transformer P N 600670 to actuate the solenoid and this will release the air pressure Plug the transformer into the corresponding outlet that is controlled with an off on switch The solenoid valve opens if there is power to the transformer so always have the switch off until ready to shoot the product into the air Use of a momentary switch is rec...

Страница 8: ... service It is a good practice to test the solenoid valve with a charge of air before loading the barrel When finished with use Remove and inspect barrel for cracks Check that cord is in good condition not pinched or broken 8 Technical Data A C Air LauncherTM Technical Data P N 101050 230VAC P N 101051 Dimensions Assembled 35 x 34 x 14 89 cm x 86 cm x 36 cm Weight 20 lb 9 kg Shipping Weight 27 lb ...

Страница 9: ...dification is not covered by this warranty Using any fluid other than what is recommended for this machine will void warranty No liability is accepted for injury or for loss damage or expense resulting from any interruption whatsoever in the operation of the product or from any consequential loss arising there from No liability is accepted for normal wear and tear We wish to satisfy YOU our custom...

Страница 10: ...eight costs to and from CITC when under the limited warranty services are the responsibility of the customer Customer must place appropriate insurance on return of product However if product is returned due to factory defect within the first year CITC will cover the cost of returning the repaired unit to the customer 6 Limited warranty services do not cause an extension of the limited warranty per...

Отзывы: