background image

Single valve installations

 Connect the spade connectors from any sensor unit to the solenoid 
tabs taking care to connect the wires according to the label. The 
solenoid cables are orange and turquoise. If these are not long enough 
they can be extended by up to 10 metres.

 

 NB:

  Should you require extension cables for the solenoid 

valves please contact Cistermiser technical services.

Multiple valve installations

Up to 3 valves can be connected in parallel using the ‘daisy chain’ cable 
provided in the additional solenoid valve kit (AVK). The AVK is available 
from Cistermiser or any major plumbing merchant. Ensure that like 
colours are connected. Use the ‘piggy back’ connectors to loop 2 or 3 
valves together as shown opposite.

  

   Valve 

installation

C

D

   SZ/LFC 

Installation

The SZ/LFC must be connected to the SZ/IF; this can be directly to one of the 2 output cables on the SZ/IF or via an 
extension”Y” cable supplied with an additional sensor kit. If required this cable can be extended up to a maximum length of 
100m with 1.5mm² cable.

 

1.  Secure the SZ/LFC to a solid surface either with screws or the sticky pads provided.

 2. 

 

Remove the top cover and pierce the appropriate rubber cable gland to connect the lights and/or fans. Take care 
when piercing the gland not to damage the product.

 

WARNING:

 Isolate mains supplies to lights and fans

 

3.  Connect the live feed for the lights to the LIGHTS contactor (Ensure load does not exceed 8A)

 

4.  Connect the live feed for the fans to the FAN contactor (Ensure load does not exceed 8A)

 

5.  Replace lid with screws provided before restoring power.

 

WARNING:

 This is a functional switching device, and must not be used for safety or maintenance isolation!

 

WARNING:

  This device is intended for use with hazardous voltages. The installation and maintenance of this device 

must be carried out by a qualifi ed electrician in accordance with local wiring regulations. Before installing 
this device, please read these installation instructions carefully.

 

NB:

 Do not install near localised heat source

 

NB:

 Where necessary use wiring conduit to protect exposed cables

8

 0118 969 1611 | [email protected] | www.cistermiser.co.uk

NB:

 Valves can be connected to any sensor. Maximum 3 valves per system.

NB:

 For grey water/rain water harvesting. Ensure adequate fi ltering is fi tted, a 10µm fi lter is recommended.

NB:  

For chemical water treatment. If the water system has been treated with chemical dosing, ensure the system is 
thoroughly fl ushed before fi tting any Cistermiser products. Concentrated chemicals in dead legs can damage the 
product and result in failure. If the water is treated with Chlorine Dioxide (ClO2), concentration levels are maintained 
below 5ppm.

NB:  

As with all water containing products, lime scale in hard water areas can affect the products performance. This can 
result in maintenance to remove the lime scale as and when required.

 Install valve on to the water supply leading into the washroom (hot, cold 
and rain/grey water) or as close as practically possible to the entry point 
to suit the pipe layout.

Содержание sensazone SZ/ASK

Страница 1: ...rface Module A sensazone Light and Fan Control 3 To control the water supply to multiple areas of a washroom simultaneously Examples include a washroom divided into different areas and a washroom with two or more entrances sensazone core product A sensazone Interface Module Additional Sensor Kits Additional Valve Kits where applicable to a maximum of 3 valves per system 4 To control the water supp...

Страница 2: ...adaptor 7 2 x universal fixing plug 8 2 x 6 x 1 1 2 screws 9 4 x 4 x 1 2 screws 10 4 x sticky pads 11 Extension cable to mains power adaptor 1 25m 12 Extension cable to solenoid valve 3m 1 sensazone Interface module 2 Sticky Pads x 2 3 Infrared Control Unit ICU 1 1 Solenoid valve either 15mm 22mm 1 or 11 4 Only supplied with 15mm or 22mm 2 2 3 4 5 6 7 8 9 10 11 12 3 2 0118 969 1611 sales cistermis...

Страница 3: ...or 22mm 4 5 Additional Sensor Kit supplied parts 1 Sensor assembly consisting of sensor unit and backplate 2 2 x universal fixing plug 3 2 x 6 x 1 1 2 screws 4 4 x sticky pads 5 Extension Y Cable 1 4 2 3 sensazone Light and Fan Control SZ LFC supplied parts 1 sensazone Light Fan Control 2 Screws x 2 3 Fixings x 2 4 Sticky Pads x 4 1 2 4 5 3 0118 969 1611 sales cistermiser co uk www cistermiser co ...

Страница 4: ... in the common entrance the water lights and fans will be activated in all areas of the washroom Example layout for single common entrance Scenario 1 and 2 Example layout for multiple entrances Scenario 3 and Scenario 4 When occupancy is detected at one of the entrances the water lights and fans will be activated in all areas of the washroom DOOR MINIMUM 1 METRE MINIMUM 1 METRE 4 0118 969 1611 sal...

Страница 5: ... Grey or rainwater supply to washroom Grey or rainwater supply to washroom Max 3 metres cable length from sensor to power supply Max 100 metre cable length between SZ IF B and SZ LFC D Max 1 85 metres cable length CEILING A A C C E E D B Detection Zone 5 metres Detection Zone 5 metres 2 2 metres 2 2 metres 5 0118 969 1611 sales cistermiser co uk www cistermiser co uk Sensor s installation Refer to...

Страница 6: ...and SZ LFC D Sensor s installation Refer to page 7 for details SZ IF installation Refer to page 7 for details SZ LFC installation Refer to page 8 for details Valve installation Refer to page 8 for details Mains power adapter Refer to page 9 for details A B D C E Cold water supply to washroom Cold water supply to washroom Isolating Valve not supplied Isolating Valve not supplied Hot water supply to...

Страница 7: ...o go out of the same exit ensure that the wire is routed around the sensor as shown in the diagram below 6 Secure sensor unit to base plate and twist clockwise to lock into position SZ IF Installation Position the sensazone Interface Module SZ IF in accordance with the following 1 The cable length from the SZ IF to the furthest valve must NOT exceed 30m 2 The cable length from the SZ IF to the SZ ...

Страница 8: ...ot exceed 8A 4 Connect the live feed for the fans to the FAN contactor Ensure load does not exceed 8A 5 Replace lid with screws provided before restoring power WARNING This is a functional switching device and must not be used for safety or maintenance isolation WARNING This device is intended for use with hazardous voltages The installation and maintenance of this device must be carried out by a ...

Страница 9: ... co uk www cistermiser co uk 4 Testing and commissioning start up operation When the sensazone is powered up the LED will be a constant amber for up to 15 seconds after which it will flash amber for 5 seconds The water supply ies into the washroom will now be on for the default run on time of 15 minutes The default run on time can be changed to 30 minutes See the ICU guide in section 7 normal oper...

Страница 10: ...device please read these installation instructions carefully SZ ASK Control classification Independent Maximum load 3 x 2W 0 33A 6VDC EMC emissions tested at load Rated temperature range 0 40 deg C Action classification Type 1 Y Pollution classification Degree 1 Ingress protection IP55 or IP65 with respect to room when smooth non porous ceiling tile used factory settings Range 2 2m high x 5m diame...

Страница 11: ...5 Component dimensions 134mm 101mm 93mm 130mm 125mm 93mm 93mm 124mm 1 valve 11 4 valve 15mm or 22mm valve 76mm 41mm 82mm 31mm 148mm 11 0118 969 1611 sales cistermiser co uk www cistermiser co uk ...

Страница 12: ...nutes Option 2 Run on time adjustment 30 minutes Sequence of programme once option has been selected Wait for single green flashing LED Wait for double green flashing LED Once your option has been chosen the LED will be constant green for 5 seconds Cup your hand over the sensor for 2 seconds to select this option The LED will be constant green for 5 seconds Cup your hand over the sensor for 2 seco...

Страница 13: ...figuring sensor sensitivity range Enter into configuration mode Point the ICU at the sensazone and press the 1 the sensor blinks green once Decrease or increase the sensor range by pressing the and buttons respectively The sensor blinks green every time or is pressed and blinks red when the minimum or maximum value is reached Press button to verify the sensor sensitivity setting the sensor display...

Страница 14: ...ttons respectively The sensor blinks green every time or is pressed and blinks red when the minimum or maximum value is reached Press button to verify the sensor light threshold setting the sensor displays the current setting by flashing green Single flash minimum sensitivity setting Double flash medium sensitivity setting Triple flash maximum sensitivity setting Save setting and exit ICU configur...

Страница 15: ... have not been exceeded There is water in one zone but not all zones Ensure water pressure does not exceed the maximum working pressure of the valve water at outlets at all times Sensor LED not lit Check electrical power supply to the sensor and all electrical connections to the valve If electrical power confirmed please contact Cistermiser for further advice Valves not opening or closing when the...

Страница 16: ...is faulty please either contact Cistermiser directly on 0118 969 1611 or at warranty cistermiser co uk with a photograph and the serial number to diagnose the cause of the problem The warranty on Cistermiser products can be extended within one year of date of manufacture at no cost to three years from the date of installation by completing the enclosed warranty card or at www cistermiser co uk war...

Отзывы: