The installer can adjust the run-on time as follows:
NB:
If a hand is held over the sensor for more than 10 seconds the sensor will go into normal operation mode.
6 Advanced settings guide – manual confi guration
Disconnect power, wait for 5 seconds and reconnect.
NB:
Sensor LED is constant amber for up to 15 seconds while checking ambient light level. If the ambient light level is
not suffi cient the sensor will automatically go into normal operation. To change settings increase light level in the room or
purchase ICU.
When fl ashing
amber
You are now in confi guration mode
If a hand is not placed over the sensor, it will go into normal operation mode.
Option 1: Run-on time adjustment (15 minutes)
Option 2: Run-on time adjustment (30 minutes)
Sequence of programme once option has been selected
Wait for
single green
fl ashing
LED.
Wait for
double green
fl ashing
LED.
Once your option
has been chosen,
the LED will be
constant green
for
5 seconds.
Cup your hand over the sensor for
2 seconds to select this option.
The LED will be
constant green for
5 seconds.
Cup your hand over the sensor for
2 seconds to select this option.
The LED will be
constant green for
5 seconds.
The LED will
then be
constant
amber
for 5
seconds.
The LED will then
fl ash amber
, giving
the opportunity to
re-enter nfi guration
mode.
1
2
3
A
B
A
B
A
B
C
Cup hand over the sensor for 2 seconds only
to enter into the run-on time confi guration
mode. LED will be constant
green
.
NB:
Manual confi guration of the sensor is not available when connected to SZ/IF.