7  Infrared Confi guration Unit (ICU) guide

 Activates cleaning mode

Activates ICU confi guration mode

Decreases setting

Increases setting

Checks the setting being altered

Saves changes and exits ICU 
confi guration mode

Quits ICU confi guration mode without 
saving changes

Confi gures sensor range

Light threshold

Fan run-on time

Confi gures run-on time

12 hour hygiene cycle activation

Resets to default factory settings

 button descriptions

 activating walk test

When the 

sensazone

 is in normal operation, point the ICU 

at the 

sensazone

 and press 

1

. The 

sensazone

 will fl ash 

green every time it detects movement. This confi rms that 
the unit is operating as it should be. After two minutes of 
no movement, the sensor returns to normal operation. The 
product must be put into ICU confi guration mode before 
any setting can be confi gured.

activating clean mode

Point the ICU at the 

sensazone

 (in normal operation mode) 

and press the clean button

. This will lock the solenoid 

valve(s) open or closed.

1 - lock open indefi nitely (steady green LED)

2 - lock closed indefi nitely (steady red LED)

3 - lock closed for 10 minutes (steady amber LED)

4 - normal operation (LED out)

Repeatedly pressing the clean mode will cycle through the 
4 states. If a delay of 4 seconds occurs after pressing the 
clean button, the valve(s) remain in that state. To return to 
normal operation press the clean button 4 times.

entering confi guration mode

Point the ICU towards the 

sensazone

 sensor and push the 

confi guration 

 button. Activation is most effective when 

the confi guration button is held down as the ICU is brought 
close to the sensor.

It can take up to 3 seconds for the product to sense the 
ICU. The 

sensazone

 will return to normal operation if there 

are no button presses for 30 seconds.

confi guring sensor sensitivity (range)

Enter into confi guration mode. Point the ICU at the 

sensazone

 and press the 

1

: the sensor blinks green once.

Decrease or increase the sensor range by pressing the 

   

and 

 buttons respectively. The sensor blinks green every 

time 

 or 

 is pressed and blinks red when the minimum 

or maximum value is reached.

Press 

 button to verify the sensor sensitivity setting: the 

sensor displays the current setting by fl ashing green.

Single fl ash:

 minimum sensitivity setting.

Double fl ash:

 medium sensitivity setting.

Triple fl ash:

 maximum sensitivity setting.

Save setting and exit ICU confi guration mode by pressing 
the 

 button. The sensor will blink green for 1 second and 

then constant amber for 3 seconds.

To exit without saving press the 

 button. 

The sensor will blink red for 1 second and then constant 
amber for 3 seconds.

NB:

 Changing sensor sensitivity will only take effect on 

the individual sensor, other sensors in the system will 
keep their range.

confi guring occupancy (run-on) time

Enter into confi guration mode. Point the ICU at the 

sensazone

 and press the 

4

: the sensor blinks green once.

Decrease or increase the run-on time by pressing the 

 

and 

 buttons respectively. The sensor blinks green every 

time 

 or 

 is pressed and blinks red when the minimum 

or maximum value is reached.

Press 

 button to verify the sensor range setting: the 

sensor displays the current setting by fl ashing green.

Single fl ash:

 15 minute run-on time set.

Double fl ash:

 30 minute run-on time set.

Save setting and exit ICU confi guration mode by pressing 
the 

 button. The sensor will blink green for 1 second and 

then constant amber for 3 seconds.

To exit without saving press the 

 button. The sensor 

will blink red for 1 second and then constant amber for 3 
seconds.

NB:

 When connected to the Interface module changes 

to occupancy time will be common across all sensors in 
the network.

NB:

 Supplied with SZ/IF

13

 0118 969 1611 | [email protected] | www.cistermiser.co.uk

Содержание sensazone SZ/ASK

Страница 1: ...rface Module A sensazone Light and Fan Control 3 To control the water supply to multiple areas of a washroom simultaneously Examples include a washroom divided into different areas and a washroom with two or more entrances sensazone core product A sensazone Interface Module Additional Sensor Kits Additional Valve Kits where applicable to a maximum of 3 valves per system 4 To control the water supp...

Страница 2: ...adaptor 7 2 x universal fixing plug 8 2 x 6 x 1 1 2 screws 9 4 x 4 x 1 2 screws 10 4 x sticky pads 11 Extension cable to mains power adaptor 1 25m 12 Extension cable to solenoid valve 3m 1 sensazone Interface module 2 Sticky Pads x 2 3 Infrared Control Unit ICU 1 1 Solenoid valve either 15mm 22mm 1 or 11 4 Only supplied with 15mm or 22mm 2 2 3 4 5 6 7 8 9 10 11 12 3 2 0118 969 1611 sales cistermis...

Страница 3: ...or 22mm 4 5 Additional Sensor Kit supplied parts 1 Sensor assembly consisting of sensor unit and backplate 2 2 x universal fixing plug 3 2 x 6 x 1 1 2 screws 4 4 x sticky pads 5 Extension Y Cable 1 4 2 3 sensazone Light and Fan Control SZ LFC supplied parts 1 sensazone Light Fan Control 2 Screws x 2 3 Fixings x 2 4 Sticky Pads x 4 1 2 4 5 3 0118 969 1611 sales cistermiser co uk www cistermiser co ...

Страница 4: ... in the common entrance the water lights and fans will be activated in all areas of the washroom Example layout for single common entrance Scenario 1 and 2 Example layout for multiple entrances Scenario 3 and Scenario 4 When occupancy is detected at one of the entrances the water lights and fans will be activated in all areas of the washroom DOOR MINIMUM 1 METRE MINIMUM 1 METRE 4 0118 969 1611 sal...

Страница 5: ... Grey or rainwater supply to washroom Grey or rainwater supply to washroom Max 3 metres cable length from sensor to power supply Max 100 metre cable length between SZ IF B and SZ LFC D Max 1 85 metres cable length CEILING A A C C E E D B Detection Zone 5 metres Detection Zone 5 metres 2 2 metres 2 2 metres 5 0118 969 1611 sales cistermiser co uk www cistermiser co uk Sensor s installation Refer to...

Страница 6: ...and SZ LFC D Sensor s installation Refer to page 7 for details SZ IF installation Refer to page 7 for details SZ LFC installation Refer to page 8 for details Valve installation Refer to page 8 for details Mains power adapter Refer to page 9 for details A B D C E Cold water supply to washroom Cold water supply to washroom Isolating Valve not supplied Isolating Valve not supplied Hot water supply to...

Страница 7: ...o go out of the same exit ensure that the wire is routed around the sensor as shown in the diagram below 6 Secure sensor unit to base plate and twist clockwise to lock into position SZ IF Installation Position the sensazone Interface Module SZ IF in accordance with the following 1 The cable length from the SZ IF to the furthest valve must NOT exceed 30m 2 The cable length from the SZ IF to the SZ ...

Страница 8: ...ot exceed 8A 4 Connect the live feed for the fans to the FAN contactor Ensure load does not exceed 8A 5 Replace lid with screws provided before restoring power WARNING This is a functional switching device and must not be used for safety or maintenance isolation WARNING This device is intended for use with hazardous voltages The installation and maintenance of this device must be carried out by a ...

Страница 9: ... co uk www cistermiser co uk 4 Testing and commissioning start up operation When the sensazone is powered up the LED will be a constant amber for up to 15 seconds after which it will flash amber for 5 seconds The water supply ies into the washroom will now be on for the default run on time of 15 minutes The default run on time can be changed to 30 minutes See the ICU guide in section 7 normal oper...

Страница 10: ...device please read these installation instructions carefully SZ ASK Control classification Independent Maximum load 3 x 2W 0 33A 6VDC EMC emissions tested at load Rated temperature range 0 40 deg C Action classification Type 1 Y Pollution classification Degree 1 Ingress protection IP55 or IP65 with respect to room when smooth non porous ceiling tile used factory settings Range 2 2m high x 5m diame...

Страница 11: ...5 Component dimensions 134mm 101mm 93mm 130mm 125mm 93mm 93mm 124mm 1 valve 11 4 valve 15mm or 22mm valve 76mm 41mm 82mm 31mm 148mm 11 0118 969 1611 sales cistermiser co uk www cistermiser co uk ...

Страница 12: ...nutes Option 2 Run on time adjustment 30 minutes Sequence of programme once option has been selected Wait for single green flashing LED Wait for double green flashing LED Once your option has been chosen the LED will be constant green for 5 seconds Cup your hand over the sensor for 2 seconds to select this option The LED will be constant green for 5 seconds Cup your hand over the sensor for 2 seco...

Страница 13: ...figuring sensor sensitivity range Enter into configuration mode Point the ICU at the sensazone and press the 1 the sensor blinks green once Decrease or increase the sensor range by pressing the and buttons respectively The sensor blinks green every time or is pressed and blinks red when the minimum or maximum value is reached Press button to verify the sensor sensitivity setting the sensor display...

Страница 14: ...ttons respectively The sensor blinks green every time or is pressed and blinks red when the minimum or maximum value is reached Press button to verify the sensor light threshold setting the sensor displays the current setting by flashing green Single flash minimum sensitivity setting Double flash medium sensitivity setting Triple flash maximum sensitivity setting Save setting and exit ICU configur...

Страница 15: ... have not been exceeded There is water in one zone but not all zones Ensure water pressure does not exceed the maximum working pressure of the valve water at outlets at all times Sensor LED not lit Check electrical power supply to the sensor and all electrical connections to the valve If electrical power confirmed please contact Cistermiser for further advice Valves not opening or closing when the...

Страница 16: ...is faulty please either contact Cistermiser directly on 0118 969 1611 or at warranty cistermiser co uk with a photograph and the serial number to diagnose the cause of the problem The warranty on Cistermiser products can be extended within one year of date of manufacture at no cost to three years from the date of installation by completing the enclosed warranty card or at www cistermiser co uk war...

Отзывы: