7 Infrared Confi guration Unit (ICU) guide
Activates cleaning mode
Activates ICU confi guration mode
Decreases setting
Increases setting
Checks the setting being altered
Saves changes and exits ICU
confi guration mode
Quits ICU confi guration mode without
saving changes
Confi gures sensor range
Light threshold
Fan run-on time
Confi gures run-on time
12 hour hygiene cycle activation
Resets to default factory settings
button descriptions
activating walk test
When the
sensazone
is in normal operation, point the ICU
at the
sensazone
and press
1
. The
sensazone
will fl ash
green every time it detects movement. This confi rms that
the unit is operating as it should be. After two minutes of
no movement, the sensor returns to normal operation. The
product must be put into ICU confi guration mode before
any setting can be confi gured.
activating clean mode
Point the ICU at the
sensazone
(in normal operation mode)
and press the clean button
. This will lock the solenoid
valve(s) open or closed.
1 - lock open indefi nitely (steady green LED)
2 - lock closed indefi nitely (steady red LED)
3 - lock closed for 10 minutes (steady amber LED)
4 - normal operation (LED out)
Repeatedly pressing the clean mode will cycle through the
4 states. If a delay of 4 seconds occurs after pressing the
clean button, the valve(s) remain in that state. To return to
normal operation press the clean button 4 times.
entering confi guration mode
Point the ICU towards the
sensazone
sensor and push the
confi guration
button. Activation is most effective when
the confi guration button is held down as the ICU is brought
close to the sensor.
It can take up to 3 seconds for the product to sense the
ICU. The
sensazone
will return to normal operation if there
are no button presses for 30 seconds.
confi guring sensor sensitivity (range)
Enter into confi guration mode. Point the ICU at the
sensazone
and press the
1
: the sensor blinks green once.
Decrease or increase the sensor range by pressing the
and
buttons respectively. The sensor blinks green every
time
or
is pressed and blinks red when the minimum
or maximum value is reached.
Press
button to verify the sensor sensitivity setting: the
sensor displays the current setting by fl ashing green.
Single fl ash:
minimum sensitivity setting.
Double fl ash:
medium sensitivity setting.
Triple fl ash:
maximum sensitivity setting.
Save setting and exit ICU confi guration mode by pressing
the
button. The sensor will blink green for 1 second and
then constant amber for 3 seconds.
To exit without saving press the
button.
The sensor will blink red for 1 second and then constant
amber for 3 seconds.
NB:
Changing sensor sensitivity will only take effect on
the individual sensor, other sensors in the system will
keep their range.
confi guring occupancy (run-on) time
Enter into confi guration mode. Point the ICU at the
sensazone
and press the
4
: the sensor blinks green once.
Decrease or increase the run-on time by pressing the
and
buttons respectively. The sensor blinks green every
time
or
is pressed and blinks red when the minimum
or maximum value is reached.
Press
button to verify the sensor range setting: the
sensor displays the current setting by fl ashing green.
Single fl ash:
15 minute run-on time set.
Double fl ash:
30 minute run-on time set.
Save setting and exit ICU confi guration mode by pressing
the
button. The sensor will blink green for 1 second and
then constant amber for 3 seconds.
To exit without saving press the
button. The sensor
will blink red for 1 second and then constant amber for 3
seconds.
NB:
When connected to the Interface module changes
to occupancy time will be common across all sensors in
the network.
NB:
Supplied with SZ/IF
13