IMPORTANT: INSTALL STEAM PIPING IN ACCORDANCE WITH ALL LOCAL

REGULATIONS AND REQUIREMENTS.

1. Set and level Cabinet in position. Machine should be level to assure proper steam

and circulation.

2. To prevent condensate draining from headers to Cabinet, piping should have a

minimum riser 12” above each respective header as illustrated on next page. Do
not make steam connection to header with a horizontal or downwardly facing tee or
elbow.

3. Whenever possible, horizontal runs or steam lines must drain, by gravity, to

respective steam header. Water pockets, or an improperly drained steam header
will provide wet steam causing improper operation of Cabinet. If pockets or im-
proper drainage cannot be eliminated, install a by-pass trap to drain condensate
from the low point in the steam supply header to the return.

4. In both the steam supply and steam return line, it is recommended that each have a

1/2” union and 1/2” globe valve. This will enable you to disconnect the steam
connections and service the Cabinet while your plant is in operation.

5. Before connecting trap and check valve to Cabinet, open globe valve in steam

supply line and allow steam to flow through Cabinet to flush out any dirt and scale
from Cabinet. This will assure proper operation of trap when connected. If steam
is dirty, it will be adviseable to install a filter or blow down line ahead of cabinet.

6. After flushing system, install trap and strainer as illustrated. Inspect trap and

strainer carefully for inlet and outlet markings and install according to
manufacturers instructions. If steam is gravity returned to boiler, omit trap but
install check valve in return line near Cabinet.

7. When cabinet is on end of a line of equipment extend headers at least 4 ft. beyond

Cabinet. Install globe valve, union, check valve and by-pass at end of line. If steam
is gravity returned to boiler, omit trap.

8. Insulate steam supply and return lines for safety of operator while servicing

Cabinet.

9. Keep Cabinet in good working condition. Repair or replace any worn or defective

parts.

The interior of the tunnel will turn white as the protective zinc oxide coating forms.
Do not try to remove this coating.
Do remove lint, dust, and boiler compound or red dust which is entrained by the steam.
Touch-up scratches and chips in the paint. A good car wax will extend life of the
painted surface.

Содержание MAN65

Страница 1: ...MUST BE GIVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER CISSELL MANUFAC...

Страница 2: ...r any special or consequential damages The liability of Cissell does not include furnishing or paying for any labor such as that required to service remove or install to diagnose troubles to adjust re...

Страница 3: ...ONS SPECIFICATIONS SPECIFICATIONS Electrical 4 amps 220V 50 Hz 1 Ph or 8 amps 115V 60 Hz 1 Ph Exhaust Duct 4 diameter with Adjustable damper for variable stack lengths Steam Supply Line 1 2 NPT Steam...

Страница 4: ...and service the Cabinet while your plant is in operation 5 Before connecting trap and check valve to Cabinet open globe valve in steam supply line and allow steam to flow through Cabinet to flush out...

Страница 5: ...Page 5 Page 5 Page 5 Page 5 Page 5...

Страница 6: ...set the machine for longer cycle times to include all differ ent garments Longer cycle times will not be harmful to the garments No more than a week should be required to select your own optimum sett...

Страница 7: ...and repair Check and replace if needed Check and replace if needed Check and replace if needed Inspect wiring and terminals Check and replace if needed Inspect wiring and terminals Check and replace...

Страница 8: ...Page 8 Page 8 Page 8 Page 8 Page 8 36...

Страница 9: ...ol Panel Cover 11 TUB1867 Lock Key 12 FB405 Cissell Nameplate 13 SC486 Roller Carriage Rod 14 FG444 Yoke 15 SF48 Clevis Pin 16 SC484 Roller Carriage Stop 17 SC478 Hanger Bar Support 18 SC482 Hanger Ba...

Страница 10: ...Page 10 Page 10 Page 10 Page 10 Page 10...

Страница 11: ...3 4 Lock Nut 20 SC520 3 4 Conduit 21 SC253 3 8x3 8Elbow 22 PT944 Solenoid Steam Valve 120V 23 AT404 Strainer Nipple Assembly 24 SC506 Mounting Bracket 25 TU2714 1 2 All Thread Nipple 26 OP296 1 2 x 5...

Страница 12: ...escription 1 FG453 Timer 3 ea 3 PT182H Relay 2 ea 4 TU13224 Relay 5 AT238 Transformer 240V Only 6 SC880 Replacement Fuse 7 Potentiometer Included as part of Timers 8 FG147 Switch Steam or Vibrator 9 A...

Страница 13: ...tion Description 1 SC166 Screw 1 4 20 x 2 2 SC107 Steam Spreader Disc 3 PT359 Washer 4 SC105 Mixing Jet Insert 5 SC106 Mixing Jet Body SAFETY GRID Optional on 120V SAFETY GRID Optional on 120V SAFETY...

Отзывы: