C A U S E
C A U S E
C A U S E
C A U S E
C A U S E
Electric power off
Loose or broken wires to start
button
Defective start switch
Defective timer cam or drive
Advance button is defective or
depressed
Defective wiring
Start button stuck or defective
Defective wiring
Defective timer
Defective wiring or short
circuit
Potentiometer knob incorrectly
set
Loose or broken wires
Defective timer
Water metering valve turned
off
Water solenoid valve defective
Water solenoid valve not
electrically energized
Defective timer
Water line clogged
Steam line clogged
Steam solenoid valve defective
Steam solenoid valve not
electrically energized
Defective timer
Moisture metering valve open
too wide
Steam trap not functioning
properly
Condensate line strainer
clogged
Motor defective
Timer defective
Relay defective
Wiring defective
Blower wheel loose
Defective blower wheel
Foreign object in blower wheel
Exhaust damper closed
Blower not operating
Exhaust duct clogged
Steam cycle too long
R E M E D Y
R E M E D Y
R E M E D Y
R E M E D Y
R E M E D Y
Turn power on.
Inspect wiring and repair.
Check and replace if needed.
Check and replace if needed.
Check and replace if needed.
Inspect wiring and terminals.
Check and replace if needed.
Inspect wiring and terminals.
Check and replace if needed.
Inspect wiring and terminals.
Reset and tighten.
Inspect wiring and terminals.
Check and replace if needed.
Open 1/4” to 1/2” turn.
Check and replace if needed.
Check wiring and terminals.
Check and replace if needed.
Clean clogged part.
Clean clogged part.
Check and replace if needed.
Inspect wiring and check valve.
Check and replace if needed.
Open 1/8” to 1/4” turn.
Check and clean or replace.
Check and clean or replace.
Check and replace if needed.
Tighten set screw.
Check and replace if needed.
Remove foreign object.
Check and repair.
Check and replace.
Clean out duct.
Check and reset.
P R O B L E M
P R O B L E M
P R O B L E M
P R O B L E M
P R O B L E M
Machine will not operate
Machine advances to “OFF”
position when started
Machine re-cycles continuously
Timing too short on one of the
three settings
Timing too long on one of the
three settings or will not
proceed through cycles
No water fog at steam jet,
steam too dry
No steam at jet
Steam too wet; excessive
moisture in cabinet
Blower will not operate
Excessive noise during drying
and steaming cycle
Excessive loss of steam or heat
around door opening