FINISHING CABINET

FINISHING CABINET

FINISHING CABINET

FINISHING CABINET

FINISHING CABINET

R e f .

R e f .

R e f .

R e f .

R e f .

P a r t

P a r t

P a r t

P a r t

P a r t

N o .

N o .

N o .

N o .

N o .

N o .

N o .

N o .

N o .

N o .

Description

Description

Description

Description

Description

1

SC489

Upper Side Access Panel

2

SC487

Lower Side Access Panel

3

SC420

Motor Mount

4

MTR88

Motor - 1/2H 110-120/220-240

50/60/1 Ph.

5

SC6

Blower Housing

6

SC790

Blower Wheel

7

SC555

Door Stop

8

SC554

Seal Bracket

9

SC553

Lower Door Seal

10

SC503

Control Panel Cover

11

TUB1867

Lock & Key

12

FB405

Cissell Nameplate

13

SC486

Roller Carriage Rod

14

FG444

Yoke

15

SF48

Clevis Pin

16

SC484

Roller Carriage Stop

17

SC478

Hanger Bar Support

18

SC482

Hanger Bar

19

SC485

Door Angle

20

SC950

Roller Carriage

21

C553

Roller (4 req’d)

22

C773

Shoulder Bolt for C553

23

SC472

Vibrator Motor

24

SC473

Base

25

SC153

Spacer

26

SC462

Door Handle

27

SC586

Left Door Assembly

28

SC587

Right Door Assembly

29

SC558

Door Bushing

30

SC461

Hinge Plate

31

SC474

Operating Nameplate

32

SC508

Damper Assembly

33

SC453

Blower Enclosure Top

34

SC406

Trim

35

SC483

Carriage Track (2 req’d)

36

Sc976

Inlet Ring

TU2844

JWC-2 Key only for TUB1867

SC855

Roller Carriage Assy. Complete
includes 16, 17, 20, 21 & 22

Содержание MAN65

Страница 1: ...MUST BE GIVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER CISSELL MANUFAC...

Страница 2: ...r any special or consequential damages The liability of Cissell does not include furnishing or paying for any labor such as that required to service remove or install to diagnose troubles to adjust re...

Страница 3: ...ONS SPECIFICATIONS SPECIFICATIONS Electrical 4 amps 220V 50 Hz 1 Ph or 8 amps 115V 60 Hz 1 Ph Exhaust Duct 4 diameter with Adjustable damper for variable stack lengths Steam Supply Line 1 2 NPT Steam...

Страница 4: ...and service the Cabinet while your plant is in operation 5 Before connecting trap and check valve to Cabinet open globe valve in steam supply line and allow steam to flow through Cabinet to flush out...

Страница 5: ...Page 5 Page 5 Page 5 Page 5 Page 5...

Страница 6: ...set the machine for longer cycle times to include all differ ent garments Longer cycle times will not be harmful to the garments No more than a week should be required to select your own optimum sett...

Страница 7: ...and repair Check and replace if needed Check and replace if needed Check and replace if needed Inspect wiring and terminals Check and replace if needed Inspect wiring and terminals Check and replace...

Страница 8: ...Page 8 Page 8 Page 8 Page 8 Page 8 36...

Страница 9: ...ol Panel Cover 11 TUB1867 Lock Key 12 FB405 Cissell Nameplate 13 SC486 Roller Carriage Rod 14 FG444 Yoke 15 SF48 Clevis Pin 16 SC484 Roller Carriage Stop 17 SC478 Hanger Bar Support 18 SC482 Hanger Ba...

Страница 10: ...Page 10 Page 10 Page 10 Page 10 Page 10...

Страница 11: ...3 4 Lock Nut 20 SC520 3 4 Conduit 21 SC253 3 8x3 8Elbow 22 PT944 Solenoid Steam Valve 120V 23 AT404 Strainer Nipple Assembly 24 SC506 Mounting Bracket 25 TU2714 1 2 All Thread Nipple 26 OP296 1 2 x 5...

Страница 12: ...escription 1 FG453 Timer 3 ea 3 PT182H Relay 2 ea 4 TU13224 Relay 5 AT238 Transformer 240V Only 6 SC880 Replacement Fuse 7 Potentiometer Included as part of Timers 8 FG147 Switch Steam or Vibrator 9 A...

Страница 13: ...tion Description 1 SC166 Screw 1 4 20 x 2 2 SC107 Steam Spreader Disc 3 PT359 Washer 4 SC105 Mixing Jet Insert 5 SC106 Mixing Jet Body SAFETY GRID Optional on 120V SAFETY GRID Optional on 120V SAFETY...

Отзывы: