TROUBLE

CAUSE

REMEDY

Check fuses on Circuit Breakers.  Make sure Main Control
Switch is ON.
Check power source; voltage, phase and frequency must be
the same as specified on Electrical Rating Plate.
Turn timer clockwise to desired time setting.
Check wire connections in electrical box on rear of dryer.
Check coils and contacts.

Check voltage at motor terminals.  Voltage must be within
+ 10% of voltage shown on Motor Rating Plate.  If not,
Check with local power company for recommended
corrective measures.

Check with local power company to insure that wiring is
adequately sized for load.
Check all electrical connections and tighten any loose
connections.
Check Installation Sheet in Service section for
recommended make-up air openings.
Clean lint accumulation on and around motors.

Close door.

Adjust switch by removing cover and bend Actuator Lever
to clear Switch Button 3/8" with cover in place.

Replace switch.

Replace contactor.

Replace V-Belt.
Adjust belt tension.
Tighten set screw.

Remove load.

No power.

Incorrect power.

Time off.
Loose wiring
connections.
Defective starting
relay.
Low voltage.

Inadequate wiring.

Loose connections.

Inadequate air.

Poor housekeeping.

Loading door
OPEN.
Door Switch out of
adjustment.

Defective Door
Switch.
Defective Basket
Motor Contractor.

V-Belt broken.
V-Belt loose.
Motor Pulley
loose.
Basket overloaded.

Motor will not start.

Motor tripping on thermal
overload.

Basket motor will not run.

Motor runs, but basket will
not revolve.

Содержание L28FD30

Страница 1: ...R1 2 07...

Страница 2: ...gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department Installation and service must be performed by a qualified ins...

Страница 3: ...ions to equipment may not be carried out without consulting with the factory and only by a qualified engineer or technician Only Cissell parts may be used WARNING Remove clothes from dryer as soon as...

Страница 4: ...service remove or install to diagnose troubles to adjust remove or replace defective equipment or a part nor does it include any responsibility for transportation expense which is involved therein The...

Страница 5: ...lustration 11 Electric Dryer Illustration 12 Gas Fired Dryer Illustration 13 Specifications 14 16 Electrical Connections 17 Gas Piping 18 Gas Piping and Gas Loop Piping Installation 19 Gas Pipe Size C...

Страница 6: ...che Ein conectado off arr t Aus desconectado Hot DoNotTouch Hei NichtBeruhren Hautetemperature Nepas toucher Caliente notocar start demarrage Start arranquedeunmovimiento emission of heat in general m...

Страница 7: ...danslesdeuxsens DrehbewigunginzweiRichtungen movimientorotativoenlosdos sentidos End of Cycle caution attention Achtung atencion precaucion directionofrotation sens de mouvement continu de rotation Dr...

Страница 8: ...ion dryer for the least amount of exhaust piping and elbows and allow free access to the rear of dryer for future servicing of belts pulleys and motors Installation clearance from all combustable mate...

Страница 9: ...l and swing panel forward Disconnect two 2 multi wire connector plugs Unscrew two 2 hold down bolts from bottom of box and one 1 bolt outside the box at the rear 5 Replace two 2 top front cover panel...

Страница 10: ...Page 10 110 lb Gas Fired Dryer Models L44CD42G and L44KD42G Illustration...

Страница 11: ...Page 11 110 lb Steam Heated Dryer Models L44CD42S and L44KD42S Illustration...

Страница 12: ...Page 12 110 lb Electric Dryer Model L44CD42E Illustration...

Страница 13: ...Page 13 110 lb Gas Fired Dryer Models L44FD42G and L44RD42G Illustration ENERGY SAVERMODEL...

Страница 14: ...rate approx 2135 lbs 968 42 kg Gas 1 crate approx 2065 lbs 936 67 kg Electric 1 crate approx 2034 lbs 922 61 kg Export Shipping Weight Steam 1 box approx 2450 lbs 111 3 kg Gas 1 box approx 2330 lbs 10...

Страница 15: ...ine 4 Coil 3 4 1 91 cm 6 Coil 3 4 1 91 cm Drying Time 110 lbs 49 9 kg dry weight Approx testing in lab Indian Head cloth 4 Coil HighPressure 100PSIGMax 70 water retention 38 min 6 Coil HighPressure 10...

Страница 16: ...102 23 kg 60 Cy 2380 lbs 1079 55 kg Export Shipping Dimensions 96 L x 49 W x 75 H 243 84 cm x 124 46 cm x 190 5 cm Export Crating 204 2 cu ft 5 78 M3 ENERGYSAVERGAS DRYERS MOTORS USED ALL 110 lb DRYER...

Страница 17: ...tional Electrical Code as ANSI NFPA No 70 Latest Edition See wiring diagram furnished with dryer Your Cissell dryer is completely wired at the factory and it is only necessary for the electrician to c...

Страница 18: ...connectedtoasingle gas service Other gas using appliances should be connected upstream from the loop WARNING LIQUIFIEDPETROLEUMGASESONLY A Gas Pressure Regulator for Liquified Petroleum Gases is not f...

Страница 19: ...Page 19 Gas Loop Piping and Gas Supply Piping System Illustrations...

Страница 20: ...00000 330000 350000 380000 400000 430000 450000 480000 504000 550000 605000 650000 705000 750000 806000 850000 907000 960000 1000000 3 4 3 4 3 4 3 4 3 4 3 4 1 1 1 1 1 4 1 1 4 1 1 2 1 1 2 1 1 2 2 2 2 2...

Страница 21: ...est pressures in excess of 1 2 PSIG 5 The dryer must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping...

Страница 22: ...e valve in steam supply line and allow steam to flow through dryer to flush out any dirt and scale from dryer This will assure proper operation of trap when connected 6 After flushing system install b...

Страница 23: ...Page 23 Steam Piping Installation Illustration...

Страница 24: ...L44FD42 MODELS L28CD30 L28UR30 L36CD30 L36UR30 L36UR36 L36AR36 L44FD42 MODELS L44CD42 L50CD42 No of Dryers Duct Diameter in inches in CM No of Dryers Duct Diameter in inches in CM No of Dryers Duct D...

Страница 25: ...Page 25 10 16cm Dryer Installation with Multiple Exhaust Illustration...

Страница 26: ...AMPLE 110 lb dryer 2000 CFM 50 000 BTU HR loss 4 Zero inches clearance to combustible material allowed on sides and at points within 4 inches of front on top 5 Heat loss into laundry room from dryer f...

Страница 27: ...g should be equal to 4 6 times the sum of dryer duct areas Provide 1 sq ft for each 6 in diameter 2 sq ft for each 8 in diameter and 4 sq ft for each 12 in diameter 2 Enclosure plenum with service doo...

Страница 28: ...of straight duct and maximum of two 90 bends 2 Use 45 and 30 elbows wherever possible 3 Exhaust each dryer separately 4 Do not install wire mesh or other restrictions in the exhaust duct 5 Use clean...

Страница 29: ...n packages of laundry and cleaning aids Heed any warnings or precautions 7 Never tumble fiberglass materials in the dryer unless the labels say they are machine dryable Glass fibers break and can rema...

Страница 30: ...ves the zinc from galvanized metal parts such as the tumbler basket If the dry cleaning machines are in the same area as the tumbler then the tumbler make up air must come from a source free of solven...

Страница 31: ...Page 31 Two Timer Models Figures 1 2 and 3 Illustrations...

Страница 32: ...lothes load The light shuts off when cooling time is completed figure 1 on page 30 4 Temperature Selector Select temperature per type of load being dried in the dryer figure 2 on page 30 High Heat Mix...

Страница 33: ...g timer completes its time then the cooling timer will be energized and the cooling light will be On When the cooling timer completes its time the cooling light will stay On and the End of Cycle light...

Страница 34: ...down part of the cycle 2 Is the lint screen blocked 3 Is the exhaust duct to the outside clean and not blocked A blocked exhaust will cause slow drying and other problems GASDRYERIGNITION The dryer h...

Страница 35: ...lectrical connections and tighten any loose connections Check Installation Sheet in Service section for recommended make up air openings Clean lint accumulation on and around motors Close door Adjust...

Страница 36: ...y Check Back Draft Damper for foreign objects lint accumulation or other causes that may prevent damper from operating Check duct work for lint build up Check installation sheet to insure that duct wo...

Страница 37: ...rmostat CLOSE door OPEN for blue flame Blow out Adjust gas pressure per Rating Plate Send to factory for correct orifices Clean exhaust Replace Radiant Sensor Replace orifices Check factory for correc...

Страница 38: ...ace thermostat Check for inlet and outlet marking on Check Valve and invert if necessary Remove plug and blow down Strainer or remove and clean thoroughly if heavily clogged Check piping per Steam Ins...

Отзывы: