Electrical Connections (with Grounding Instructions Illustration)
ELECTRICAL
CONNECTIONS
FOR ALL DRYERS
Dryers must be electrically grounded
by a separate #14 or larger
green wire from the
grounding terminal
within the service connection
box, to a cold water pipe. In all cases, the grounding method must
comply with
local electrical code requirements
; or in the absence of
local codes, with the
National Electrical Code as ANSI/NFPA No.
70—Latest Edition
.
See wiring diagram furnished with dryer.
Your Cissell dryer is
completely wired at the factory and it is only necessary for the
electrician to connect the power leads to the wire connectors within
the service connection box on the rear of the dryer.
Do not change
wiring without consulting the factory, as you may void the factory
warranty.
DO NOT CONNECT THE DRYER TO ANY
VOLTAGE OR CURRENT OTHER THAN THAT SPECIFIED
ON THE DRYER RATING PLATE.
(Wiring diagram is located on
rear wall of dryer.)
All panels must be in position before operation of dryer.
Содержание L28FD30
Страница 1: ...R1 2 07...
Страница 10: ...Page 10 110 lb Gas Fired Dryer Models L44CD42G and L44KD42G Illustration...
Страница 11: ...Page 11 110 lb Steam Heated Dryer Models L44CD42S and L44KD42S Illustration...
Страница 12: ...Page 12 110 lb Electric Dryer Model L44CD42E Illustration...
Страница 13: ...Page 13 110 lb Gas Fired Dryer Models L44FD42G and L44RD42G Illustration ENERGY SAVERMODEL...
Страница 19: ...Page 19 Gas Loop Piping and Gas Supply Piping System Illustrations...
Страница 23: ...Page 23 Steam Piping Installation Illustration...
Страница 25: ...Page 25 10 16cm Dryer Installation with Multiple Exhaust Illustration...
Страница 31: ...Page 31 Two Timer Models Figures 1 2 and 3 Illustrations...