9
3
Remove the cover plate at the back of the machine. (See dimensions
(E)).
Connect the power cable to the connectors.
220V 3AC
220V 3 phase (3AC) should be connected to the connectors “
L1,L2,L3
”.
The green/yellow grounding clamp has to be connected to the groun-
ding wire “
PE
”.
380 V 3AC + N
380 V 3 phase (3AC + N) has to be connected to the connectors
“L1,L2,L3”
,
the blue neutral to the “N” connector
.
The green/yellow grounding clamp has to be connected to the groun-
ding wire “
PE
”.
After connection, check the
spin direction
. The cylinder must spin in
the
direction of the arrow
, showed on the sticker on the door window
(
clockwise
).
A wrong spin direction can damage the motor, and can also cause water
to spurt from the soap dispenser.
In case of
wrong spin direction:
switch the terminal clamps of the motor
circuit “R” and “S” of the connecting cable.
The diameter of the main drain should be adapted to the water flow and
the number of machines. It should be sufficient to handle at least 80L/
min. per machine.
It is necessary to connect the main drain at least on one side to an open
air-brake to allow ventilation.
The machine is equipped with a drain valve with 6/4" outer diameter (50
mm). This drain valve should be connected to the drain by means of the
drain elbow which is delivered with the machine.
S
S
Main power connection
Water drain
S
S
S
Power of the breaker plugs:
machine with steam heating or boiler fed machines without additio-
nal electrical heating
Heating:
220V 3AC
380V 3AC + N
4,2 kw
16A
16A
6 kw
16A
16A
12 kW
40 A
20 A
15 kW
50 A
25 A
18 kW
50 A
32 A
21 kW
----
40 A
24 kW
----
40 A
machine with electrical heating
220V 3AC
380V 3AC + N
16 A
16 A