21
B
A
Before opening the door, check that all the water has been drained from the
tub and that the cylinder has come to a complete stop.
Important:
Remote stop function
By means of this function,
no cycles can be selected anymore during a certain
period of time
(e.g. between 10 p.m. and 7 a.m.). This time is determined by an
extern timer
. As soon as the last cycle is finished,
“
OFF
“ (blinking) appears on the left display as long as this function is
activated.
Cool down
This function allows to gradually lower the temperature of the wash bath to
prevent creasing of the linen.
During a cool down, the remaining program time on the central display will be
replaced by “
cd
”.
Power Failure
Should the power fall out during the program, the water will be drained and the
door can be opened after maximum 3 minutes. When the door remains locked,
and the power comes back up within 24 hours, the program will continue from
there, where it was at the time of the power failure.
If due to breakdown, the door is not unlocked automatically, you have to remove
the service panel (A) below and pull the ring (B), suspended on the left side, while
opening the door.
Thermo-magnetic motor protection
If the program switches off due to overheating of the motors and
the thermo-
magnetic protection
shuts them down, the left display will alternately show
“
Mot
” and the temperature of the wash bath. This can occur during:
washing
All movement is halted but the water remains in the tub. When the motors switch
back on again, the program will continue to run where it left of.
spinning
All movement is halted and the water is drained. When the motors are switched
on again, the spinning phase will be skipped.
Remark
If the thermo-magnetic motor-protection switches on for the fifth time during
the same program, this program will be immediately terminated.
Содержание CHMW35-WE55-165
Страница 1: ......