Page 24
Dryer Installation with Multiple Exhaust
DRYER INSTALLATION
WITH MULTIPLE
EXHAUST
EXAMPLE
For Exhaust Duct more than 14 feet (5 m) and 2 elbows
equivalent and more than 0.3 inches (8 mm) static pressure.
(See illustration on previous page.)
1.
Make-up air from outside building may enter enclosure from
top or side walls. (See Dryer Make-up Air Requirements Chart)
2 .
Use constant diameter duct with area equal to the sum of dryer
duct areas.
EXAMPLE: 6-8 inch (153-204 mm) diameter duct = 1-19.6 inch
(26-498 mm) diameter duct in area. Use 20 inch (508 mm)
diameter duct or diameter to match tube-axial fan.
3.
Enclosure (plenum) with service door. This separates the dryer
air from room comfort air. If dryers use room air instead of
outside air, the heat loss can be another 25 Btu/h (6.3 kcal/h)
for each cubic foot per minute (cfm) used.
4 .
Zero inches clearance to combustible material allowed on sides
and at points within 4 inches (102 mm) of front on top.
5 .
Heat loss into laundry room from dryer fronts only is about
60 Btu/h (16 kcal/h) per square root.
6 .
Flange mounted, belt driven tube-axial fan. Fan must be run
when one or more dryers are running. See suggested
Automatic Electrical Control Wiring Diagram on previous page.
Must meet local electrical codes. Fan air flow (cfm) is equal to
sum of dryer air flows, but static pressure (sp) is dependent on
length of pipe and number of elbows.
7.
Barometric Bypass Damper - Adjust to closed flutter
position with all dryers and exhaust fan running. Must be
located with enclosure.
CAUTION
Never install hot water heaters or other gas appliances in
the same room as dryers. Never install cooling exhaust fans
in the same room as dryers.
Содержание C150G
Страница 11: ...Page 11 150 lb C Models Gas Fired Dryer Illustration ...
Страница 14: ...Page 14 Gas Piping Installation Illustration ...
Страница 16: ...Page 16 150 lb Steam Heated Models Illustration ...
Страница 23: ...Page 23 Dryer Installation with Multiple Exhaust Illustration ...
Страница 31: ...Page 31 Two Timer Models Figures 1 2 and 3 Illustrations ...
Страница 33: ...Page 33 Moisture Control Illustration ...
Страница 41: ...Page 41 DIRECT SPARK IGNITION OPERATION FLOW CHART ...
Страница 45: ...Page 45 Basket Alignment for 150 lb Dryers Illustrations ...
Страница 47: ...Page 47 Shimming the Basket and Spider Assembly Illustration ...
Страница 54: ...Page 54 150 lb Dryer Front of Dryer Illustration ...
Страница 56: ...Page 56 150 lb Dryer Rear of Dryer Illustration ...
Страница 67: ...Page 67 ...