C-2
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Appendix C RAID Controller Considerations
Supported RAID Controllers and Required Cables
Supported RAID Controllers and Required Cables
This server supports the RAID controller options and cable requirements shown in
Table C-1
for small
form factor drives and
Table C-2
for large form factor drives.
Caution
Do not mix controller types in the server. Do not use the embedded MegaRAID controller and a hardware
RAID controller card at the same time. This is not supported and could result in data loss.
Table C-1
Cisco UCS C220 M3 Small Form Factor Drives RAID Options
Controller
Style
Maximum
Drives
SCPM
1
1. SCPM = SuperCap power module (RAID backup unit). See
RAID Backup Units, page C-4
.
Embedded MegaRAID
2
2. Migrations from a RAID card to the embedded controller are not supported after-factory. See
RAID Controller Migration, page C-6
.
Onboard
4 SATA or
8 SAS
internal
3
3. Support for eight SAS drives requires an optional SCU upgrade ROM module on the motherboard.
No
0, 1, 5
4
4. Support for RAID 5 requires an optional RAID 5 software key module on the motherboard.
, 10
4 drives:
1 mini-SAS (UCSC-CABLE1
5
5. UCSC-CABLE1 is a kit of two mini-SAS cables. This pair of cables is shipped with every new system.
)
8 drives:
2 mini-SAS (UCSC-CABLE1)
Cisco UCS RAID SAS
2008M-8i:
PID
UCSC-RAID-MZ-C220
Mezzanine
8 internal
No
0, 1, 1E, 10
4 drives:
1 mini-SAS (UCSC-CABLE1)
8 drives:
2 mini-SAS (UCSC-CABLE1)
Cisco UCS RAID SAS
2008M-8i:
PID
UCSC-RAID-11-C220
(Includes RAID 5 & 50)
Mezzanine
8 internal
No
0, 1, 1E, 5, 10,
50
4 drives:
1 mini-SAS (UCSC-CABLE1)
8 drives:
2 mini-SAS (UCSC-CABLE1)
LSI MegaRAID SAS
9266CV-8i
PCIe
8 internal
SCPM
0, 1, 5, 6, 10,
50, 60
4 drives:
1 mini-SAS (UCSC-CABLE1)
8 drives:
2 mini-SAS (UCSC-CABLE1)
LSI MegaRAID SAS
9271-8i
PCIe
8 internal
No
0, 1, 5, 6, 10,
50, 60
4 drives:
1 mini-SAS (UCSC-CABLE1)
8 drives:
2 mini-SAS (UCSC-CABLE1)
LSI MegaRAID SAS
9271CV-8i
PCIe
8 internal
SCPM
0, 1, 5, 6, 10,
50, 60
4 drives:
1 mini-SAS (UCSC-CABLE1)
8 drives:
2 mini-SAS (UCSC-CABLE1)
LSI MegaRAID SAS
9285CV-8e
PCIe
8 external
SCPM
0, 1, 5, 6, 10,
50, 60
Not sold by Cisco
LSI MegaRAID SAS
9286CV-8e
PCIe
8 external
SCPM
0, 1, 5, 6, 10,
50, 60
Not sold by Cisco
RAID Levels
Required Cables
Содержание UCS C220 M3
Страница 12: ...xii Cisco UCS C220 Server Installation and Service Guide OL 25760 01 Preface ...
Страница 14: ...xiv Cisco UCS C220 Server Installation and Service Guide OL 25760 01 Preface ...
Страница 20: ...1 6 Cisco UCS C220 Server Installation and Service Guide OL 25760 01 Chapter 1 Overview ...
Страница 134: ...D 2 Cisco UCS C220 Server Installation and Service Guide OL 25760 01 Appendix D Installation for Cisco UCS Integration ...