Cisco UCS C200 Server Installation and Service Guide
OL-20732-02
Chapter 2 Installing the Server
Installing the Server Into a Rack
Figure 2-2
Attaching a Slide-Rail Assembly
Note
The mounting pegs that protrude through the rack-post holes are designed to fit round or square #12-24
holes, or #10-32 holes when the mounting peg is compressed (see
Figure 2-3
). If your rack has #10-32
rack-post holes, align the mounting pegs with the holes and then compress the spring-loaded pegs to
expose the #10-32 inner peg.
Figure 2-3
Spring-Loaded Mounting Pegs
c.
Pull the inner slide rails on each assembly out toward the rack front until they hit the internal stops
and lock in place.
1
Front-left rack post
4
Length-adjustment bracket
2
Rear-left rack post
5
Locking clip (one on each end of assembly)
3
Slide-rail assembly
6
Mounting pegs (two on each end of assembly)
1
3
5
2
6
4
195968
1
Pegs in standard (uncompressed) position
2
Pegs compressed to expose 10-32 inner peg
33
0245
1
2