Cisco UCS B200 Blade Server Installation and 
Service Note

The UCS B200 blade server (shown in 

Figure 1

) is now only available in the M2 version (the M1 version 

is no longer sold as of 1/21/2011). The procedures in this document apply to both versions. The Cisco 
UCS B200 is a half-width blade with 12 DIMM slots; it supports one adapter. You may install up to eight 
UCS B200 Blade Servers to a UCS chassis.

Figure 1

Cisco UCS B200 Front Panel

1

Asset tab 

1

1.

Each server has a blank plastic tag that pulls out of the front panel, provided so you can add your 
own asset tracking label without interfering with the intended air flow. 

7

Network link status LED

2

Blade ejector handle

8

Blade health LED

3

Ejector captive screw

9

Console connector

4

Hard drive bay 1

10

Reset button access

5

Hard drive bay 2

11

Beaconing LED and button

6

Power button and LED

195354

4

5

1

2

3

6

7

8

9

10

11

Содержание UCS B200

Страница 1: ... Cisco UCS B200 is a half width blade with 12 DIMM slots it supports one adapter You may install up to eight UCS B200 Blade Servers to a UCS chassis Figure 1 Cisco UCS B200 Front Panel 1 Asset tab 1 1 Each server has a blank plastic tag that pulls out of the front panel provided so you can add your own asset tracking label without interfering with the intended air flow 7 Network link status LED 2 ...

Страница 2: ...a state where it can be restarted quickly If the desired power state for a service profile associated with a blade server or an integrated rack mount server is set to off using the power button or Cisco UCS Manager to reset the server will cause the desired power state of the server to become out of sync with the actual power state and the server may unexpected shutdown at a later time To safely r...

Страница 3: ...a direct connection to the operating system and the BIOS running on a blade server Figure 2 KVM Cable for Blade Servers Conventions This document uses the following conventions for notes cautions and safety warnings Notes and Cautions contain important information that you should know Note Means reader take note Notes contain helpful suggestions or references to material that are not covered in th...

Страница 4: ...isia vammoja Ennen kuin käsittelet laitteistoa huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla SÄILYTÄ NÄMÄ OHJEET Attention IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce sy...

Страница 5: ...o significa perigo Você está em uma situação que poderá ser causadora de lesões corporais Antes de iniciar a utilização de qualquer equipamento tenha conhecimento dos perigos envolvidos no manuseio de circuitos elétricos e familiarize se com as práticas habituais de prevenção de acidentes Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos avisos de segur...

Страница 6: ...Se n d d o c u m e n t c o m m e n t s t o u c s d o c f e e d b a ck c i s c o c o m 6 Cisco UCS B200 Blade Server Installation and Service Note OL 22473 02 ...

Страница 7: ...nção de acidentes Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo GUARDE ESTAS INSTRUÇÕES Advarsel VIGTIGE SIKKERHEDSANVISNINGER Dette advarselssymbol betyder fare Du befinder dig i en situation med risiko for legemesbeskadigelse Før du begynder arbejde på udstyr skal du være opmærksom på de inv...

Страница 8: ...Se n d d o c u m e n t c o m m e n t s t o u c s d o c f e e d b a ck c i s c o c o m 8 Cisco UCS B200 Blade Server Installation and Service Note OL 22473 02 ...

Страница 9: ...dges only Note Seagate SATA disks and Intel or Samsung SATA SSDs are not supported in UCS Manager release 1 2 1 and can not be used with servers using UCS Manager release 1 2 1 Caution RAID array migration between a B200 M1 or B200 M2 and a B200 M3 is not supported Replacing an HDD or SSD with a drive of the same size model and manufacturer generally causes few problems with UCS Manager If the dri...

Страница 10: ...arlier software eleases A03 D146GA2 3 3 This part reached end of sale on 12 16 2011 146 GB 6Gb SAS transfer rate2 10K RPM SFF HDD hot plug drive sled mounted A03 D146GC2 146 GB 6Gb SAS transfer rate2 10K RPM SFF HDD hot plug drive sled mounted A03 D300GA2 300 GB 6Gb SAS transfer rate2 10K RPM HDD hot plug drive sled mounted A03 D600GA2 600 GB 6Gb SAS transfer rate2 10K RPM HDD hot plug drive sled ...

Страница 11: ...ly reinstalling it in another blade server Step 3 Install a blank faceplate N20 BBLKD to keep dust out of the blade server if the slot will remain empty Installing a Blade Server Hard Drive To install a blade server hard drive in a blade server follow these steps Step 1 Place the hard drive lever into the open position by pushing the release button see Figure 4 Figure 4 Installing a Hard Drive in ...

Страница 12: ...r The server can run in two power modes Main power mode Power is supplied to all server components and any operating system on your hard drives can run Standby power mode Power is supplied only to the service processor and the cooling fans and it is safe to power off the server from this mode After establishing a connection to the blade server s operating system you can directly shut down the blad...

Страница 13: ... move to removing the server Removing a Cisco UCS B200 Blade Server Using UCS Manager decommission the server using UCS Manager before physically removing the server To remove a blade server from the chassis follow these steps Step 1 Loosen the captive screw on the front of the blade Step 2 Remove the blade from the chassis by pulling the ejector lever on the blade until it unseats the blade serve...

Страница 14: ...ten the captive screw on the front of the blade to no more than 3 in lbs Tightening with bare fingers only is unlikely to lead to stripped or damaged captive screws Step 6 Power on the server UCS Manager will automatically re acknowledge reassociate and recommission the server provided any hardware changes are allowed by the service profile Figure 5 shows the positioning of a blade server in the c...

Страница 15: ...ing a Blade Server Cover Figure 6 Opening a Cisco UCS B200 Blade Server Air Baffles The air baffles shown in Figure 7 ship with all M2 models they direct and improve air flow for the server components No tools are necessary to install them just place them over the DIMMs as shown Figure 7 Cisco UCS B200 Air Baffles 252001 1 2 1 Left Baffle 2 Right Baffle 278698 2 1 ...

Страница 16: ...e saved and if you remove the blade from the chassis the LED values will persist for up to 10 minutes Pressing the LED diagnostics button on the motherboard will cause the LEDs that currently show a component fault to light for up to 30 seconds for easier component identification LED fault values are reset when the blade is reinserted into the chassis and booted and the process begins from its sta...

Страница 17: ...teps Step 1 Remove a motherboard CMOS battery a Power off the blade remove it from the chassis and remove the top cover as described in the Removing a Blade Server Cover section on page 14 b Press the battery socket retaining clip toward the chassis wall see Figure 9 c Lift the battery from the socket Use needle nose pliers to grasp the battery if there is not enough clearance for your fingers Ste...

Страница 18: ...d for the second CPU will not be recognized if the second CPU is not present see Memory Arrangement You may need to use these procedures to move a CPU from one server to another or to replace a faulty CPU Table 3 and Table 4 show the available CPU options 253408 Table 3 CPU Options M1 Models Product ID Power Draw W Clock Speed DDR3 Cache N20 X00001 Xeon X5570 95W 2 93 GHz 1333 8MB N20 X00002 Xeon ...

Страница 19: ...ctive cover See Figure 10 callout 5 Table 4 CPU Options M2 Models Product ID Power Draw W Clock Speed DDR3 MHz Cache N20 X00001 Xeon X5570 95 W 2 93 GHz 1333 8MB N20 X00002 Xeon E5540 80 W 2 53 GHz 1066 8MB N20 X00003 Xeon E5520 80 W 2 26 GHz 1066 8MB N20 X00004 Xeon L5520 60W 2 26 GHz 1066 8MB N20 X00006 Xeon X5550 95 W 2 66 GHz 1333 8 MB N20 X00009 Xeon E5504 80 W 2 00 GHz 800 8 MB A01 X0100 Xeo...

Страница 20: ...ver verify the following The CPU is supported for that model server A BIOS is available and installed that supports the CPU DIMM and server combination The service profile for this server in UCS Manager will recognize and allow the new CPU This is especially important if you have been using a single processor and install a second processor To install a CPU and heat sink follow these steps Step 1 P...

Страница 21: ...or an equivalent may also be used add a protective film of thermal compound to the bottom of the heat sink where it will contact the CPU See Figure 11 callout 4 Step 5 Replace the heat sink N20 BHTS1 See Figure 11 callout 5 Caution For proper cooling align the arrows on the installed heat sink to point to the front and back of the blade Make sure that the heat sink fins are aligned to run along th...

Страница 22: ...GB2 8 GB DDR3 1333 MHz RDIMM PC3 10600 dual rank 2Gb DRAMs N01 M304GB1 L 4 GB DDR3 1333 MHz RDIMM PC3 10600 dual rank Low Voltage1 1 Low voltage DIMMs require Cisco UCS Manager version 1 2 1 or later and the related BIOS package N01 M308GB2 L 8 GB DDR3 1333 MHz RDIMM PC3 10600 dual rank Low Voltage1 UCS MR 1X041RX A 4 GB DDR3 1333 MHz RDIMM PC3 10600 single rank Low Voltage Table 6 Cisco Systems S...

Страница 23: ...g Mode Enables low voltage memory operation This setting is available only if all DIMMs installed are low voltage DIMMs Performance Mode Disables low voltage memory operation If you mix low voltage DIMM pairs with standard voltage DIMM pairs the system defaults to this setting Step 5 Press F10 to save your changes and exit the setup utility or you can exit without saving changes by pressing Esc UC...

Страница 24: ... within the Blade Server Each channel is identified by a letter A B C for CPU1 and D E F for CPU 2 Each DIMM slot is identified by a number either 1 or 2 Note that each DIMM slot 1 is blue while each slot 2 is black Figure 14 shows how DIMMs and channels are physically laid out on the blade server The DIMM slots in the upper right are associated with the right CPU while the DIMM slots in the lower...

Страница 25: ...er for installing upgrade DIMMs and while other configurations may work if problems arise moving them to the preferred arrangement should help Memory Performance When considering the memory configuration of your blade server there are several things you need to consider For example DIMMs within the blade server should all be the same type This goes for both speed and size Do not mix different size...

Страница 26: ...t be optimal Recommendations for achieving performance of 1333 MHz on B200 M2 servers Use Intel Xeon X5680 X5670 or X5650 processors see Table 4 Use only Cisco certified single or dual rank DIMMs that support 1333 MHz speeds see Table 6 DIMMs do not have to be identical in type or capacity but beware of the caveats listed in the section below regarding performance degradation Always set the system...

Страница 27: ...ollow these steps Step 1 Position the adapter board connector above the mother board connector and align the three adapter captive screws to the posts on the motherboard Step 2 Firmly press the adapter connector into the motherboard connector Step 3 Tighten the three captive screws Table 8 Adapter Card Options Cisco Product ID Name N20 AI0002 Cisco UCS 82598KR CI 10 Gb Ethernet Adapter N20 AQ0002 ...

Страница 28: ...roubleshooting Guide Server Configuration UCS servers are intended to be configured and managed using UCS Manager Refer to the UCS Manager Configuration Guide appropriate for your UCS Manager version Server Specifications 1 2 1 1 1 3 252005 Table 9 Physical Specifications for the Cisco UCS B200 Blade Server Specification Value Height 1 95 inches 50 mm Width 8 00 inches 203 mm Depth 24 4 inches 620...

Страница 29: ...technical documentation as an RSS feed and deliver content directly to your desktop using a reader application The RSS feeds are a free service Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and or its affiliates in the U S and other countries To view a list of Cisco trademarks go to this URL www cisco com go trademarks Third party trademarks mentioned are the property o...

Страница 30: ...u m e n t c o m m e n t s t o u c s d o c f e e d b a ck c i s c o c o m 30 Cisco UCS B200 Blade Server Installation and Service Note OL 22473 02 Related Documentation 2009 2012 Cisco Systems Inc All rights reserved ...

Отзывы: