Wattage
Source
Fabric Interconnect
Cisco PID
930 W
-48 VDC
Cisco UCS 6332 and
Cisco UCS 6332-16UP
UCS-PSU-6332-DC
1230 W
240 to 380 VDC
Cisco UCS 6332 and
Cisco UCS 6332-16UP
N9K-PUV-1200W
Figure 7: AC Power Supply for the Cisco UCS 6332 and UCS 6332-16UP Fabric Interconnect
Power supplies have two LEDs: one for power status and one for a failure condition.
Green power on LED
2
Amber fault/error LED
1
Description
State
LED
Power supply is on and functioning properly
Solid green
Power on LED
3.3 V voltage standby (VSB) is on but the power supply is not
powering the other units
Blinking green
Power on LED
There is no AC power to the power supply
Off
Power on LED
Power supply failure that indicates an over voltage, over current,
or over temperature
Solid amber
Fault/error LED
AC power is present, 3.3 VSB is on, and the power supply is
off
Blinking amber
Fault/error LED
Normal operation
Off
Fault/error LED
If one power supply is installed in the chassis, but the other power supply slot is empty, a blank filler panel
should be used to cover the empty slot.
Cisco UCS 6300 Series Fabric Interconnect Hardware Installation Guide
7
Product Overview
Power Supplies