Wait for approximately two minutes to let the server boot in standby power during the first bootup.
You can verify system power status by looking at the system Power Status LED on the front panel (see
LED Indicators
on Cisco SNS 3515 and 3595 Appliances, on page 1
). The system is in standby power mode when the LED is amber.
Step 2
Plug your management Ethernet cable into the dedicated management port on the rear panel (see
Cisco SNS 3515 or
SNS 3595 Appliance Back Panel View, on page 6
).
Step 3
Allow your preconfigured DHCP server to assign an IP address to the server node.
Step 4
Use the assigned IP address to access and log in to the Cisco IMC for the server node. Consult with your DHCP server
administrator to determine the IP address.
The default user name for the server is admin. The default password is password.
Note
Step 5
From the Cisco IMC Server Summary page, click Launch KVM Console. A separate KVM console window opens.
Step 6
From the Cisco IMC Summary page, click Power Cycle Server. The system reboots.
Step 7
Select the KVM console window.
The KVM console window must be the active window for the following keyboard actions to
work.
Note
Step 8
When prompted, press F8 to enter the Cisco IMC Configuration Utility. This utility opens in the KVM console window.
This utility has two windows that you can switch between by pressing F1 or F2.
Step 9
Continue with
Setup CIMC Configuration Utility, on page 31
.
Cisco Integrated Management Controller
You can monitor the server inventory, health, and system event logs by using the built-in Cisco Integrated
Management Controller (CIMC) GUI or CLI interfaces. See the user documentation for your firmware release
at the following URL:
http://www.cisco.com/c/en/us/support/servers-unified-computing/ucs-c-series-integrated-management-controller/
products-installation-and-configuration-guides-list.html
Setup CIMC Configuration Utility
The following procedure is performed after you connect to the system and open the Cisco IMC Configuration
Utility.
Step 1
Set NIC mode and NIC redundancy:
a) Set the NIC mode to choose which ports to use to access Cisco IMC for server management:
•
Shared LOM EXT (default)
—
This is the shared LOM extended mode, the factory-default setting. With this
mode, the Shared LOM and Cisco Card interfaces are both enabled.
In this mode, DHCP replies are returned to both the shared LOM ports and the Cisco card ports. If the system
determines that the Cisco card connection is not getting its IP address from a Cisco UCS Manager system
Cisco SNS 3500 Series Appliance Hardware Installation Guide
31
Install the Cisco SNS 3515 and Cisco SNS 3595 Hardware Appliances
Cisco Integrated Management Controller