Performance Route Processor Installation and Configuration Guide
OL-11656-01
Upgrading Chopper FPGA on PRP-2
Note
Upgrading Chopper FPGA on PRP-2 is supported from Cisco IOS release
12.0(32)SY11 and Cisco IOS release 12.0(33)S6 onwards.
When to upgrade?
You can identify the PRPs that require upgrade using the following ways:
1.
A warning message is displayed in the console on router bootup for the PRPs
that require upgrade.
Example:
00:00:45: %FPD_MGMT-3-INCOMP_IMG_VER: Incompatible CHOPPER PROM FP
(FPD
ID=1) image version detected for PRP-2 card in slot 0. Detected
version
= 2.149, minimum required version = 2.151. Current HW version =
10242.6.
00:00:45: %FPD_MGMT-4-UPGRADE_REQUIRED: FPD Image Upgrade is
required
for PRP-2 card in slot 0
2.
Check the version details on the
show hw-module all fpd
CLI. The
difference in current version and minimum required version indicates the
upgrade required.
Upgrade Procedure
To perform Chopper FPGA upgrade on PRP-2, follow these steps:
Step 1
Ensure both RP's IOS software are upgraded to the release to be upgraded.
Step 2
Ensure the redundancy system is RPR+/SSO mode using
show redundancy
CLI.
Step 3
Ensure minimal non-critical traffic via the system. This command should be run
only in a maintenance window, as the upgrade can take 3-4 minutes maximum and
needs to be done at one single shot.