23
Performance Route Processor Installation and Configuration Guide
OL-11656-01
Removing and Installing a PRP
Figure 6
shows the ejector levers in detail.
Figure 6
Ejector Lever Detail (Cisco 12404 shown)
To remove a PRP, follow these steps:
Step 1
If you are replacing the PRP in a system with only one PRP, copy the currently
running configuration file to a TFTP server or to a Flash disk so that you can
retrieve it later.
Step 2
Turn off system power.
Step 3
Attach an ESD-preventive wrist strap and follow its instructions for use.
Step 4
If you are replacing a PRP, disconnect any devices that are attached to the
Ethernet, console, or auxiliary ports. If you are removing a PRP for maintenance
and will reinstall the same one, you can leave the devices attached, provided that
doing so will not strain the cables.
Step 5
Using a 3/16-inch flat-blade screwdriver, loosen the two captive screws on the
ends of the PRP.