5-11
Cisco Redundant Power System Hardware Installation Guide
OL-3654-01
Chapter 5 Troubleshooting the Cisco RPS
Error Messages on Cisco 2600 Series and Cisco 3620, Cisco 3640, and Cisco 3725 Routers
Error Description:
The temperature inside the Cisco RPS is too hot.
SNMP Trap Issued Upon Error:
ciscoEnvMonRedundantSupplyNotification is generated.
The varbinds included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState.
The value of ciscoEnvMonSupplyState is a warning.
How to Correct Error:
•
Check the temperature of the room where the Cisco RPS is located, and
correct the temperature setting if it is above 40
o
C.
•
Check the front and rear panels of the Cisco RPS to make sure they are clear
of any obstructions.
•
If the error message persists, replace the Cisco RPS.
Console Message Issued Upon Correction of Error:
•
When an external device console screen displays the Cisco IOS software
prompt (routername> or routername#)
Redundant Power Supply THERMAL condition is now normal
•
When an external device console screen displays the ROMMON prompt
(
rommon#>
), no console message is issued when the error is corrected.
SNMP Trap Issued Upon Correction of Error:
ciscoEnvMonRedundantSupplyNotification is generated.
The varbinds included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState.
The value of ciscoEnvMonSupplyState is a warning.