Chapter 5 Troubleshooting the Cisco RPS
Error Messages on Cisco 2600 Series and Cisco 3620, Cisco 3640, and Cisco 3725 Routers
5-8
Cisco Redundant Power System Hardware Installation Guide
OL-3654-01
Console Error Message:
•
When an external device console monitor screen displays the Cisco IOS
software prompt (
routername>
or
routername#
)
System detected Redundant Power Supply AC FAIL condition.
The Cisco IOS software checks the condition every 30 seconds. If the
condition still exists, the error message reappears.
•
When an external device console monitor screen displays the ROMMON
prompt (
rommon#>
)
*** System Environmental Interrupt ***
WARNING: REDUNDANT POWER SUPPLY AC FAIL BIT IS ASSERTED.
Error Description:
One of the AC modules has been turned off or has been disconnected or has failed.
See
Table 5-1
for details. The Cisco IOS software checks the condition every 30
seconds. If the condition still exists, the error message reappears.
SNMP Trap Issued Upon Error:
ciscoEnvMonRedundantSupplyNotification is generated.
The varbinds included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState.
The value of ciscoEnvMonSupplyState is a warning.
How to Correct Error:
Check the AC LEDs on the Cisco RPS to determine which AC module is reporting
the error, and try the corrective actions described in
Table 5-1
.
Console Message Issued Upon Correction of Error:
•
When an external device console monitor screen displays the Cisco IOS
software prompt (
routername>
or
routername#
)
Redundant Power Supply AC condition is now normal.
•
When an external device console monitor screen displays the ROMMON
prompt (
rommon#>
), no console message is issued when the error is corrected.