Chapter 5 Troubleshooting the Cisco RPS
Error Messages on Cisco 2600 Series and Cisco 3620, Cisco 3640, and Cisco 3725 Routers
5-10
Cisco Redundant Power System Hardware Installation Guide
OL-3654-01
How to Correct Error:
The Cisco RPS continues to operate with a single fan failure, but to correct the
failure, replace the Cisco RPS.
Console Message Issued Upon Correction of Error:
•
When an external device console monitor screen displays the Cisco IOS
software prompt (
routername>
or
routername#
)
Redundant Power Supply THERMAL condition is now normal.
•
When an external device console screen displays the ROMMON prompt
(
rommon#>
), no console message is issued when the error is corrected.
SNMP Trap Issued Upon Correction of Error:
ciscoEnvMonRedundantSupplyNotification is generated.
The varbinds included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState.
The value of ciscoEnvMonSupplyState is a warning.
Temperature Error
LED status:
TEMP LED is amber.
Console Error Message:
•
When an external device console monitor screen displays the Cisco IOS
software prompt (
routername>
or
routername#
)
System detected Redundant Power Supply THERMAL FAIL condition.
The Cisco IOS software checks the condition once every 30 seconds. If the
condition still exists, the error message reappears.
•
When an external device console screen displays the ROMMON prompt
(
rommon#>
)
*** System Environmental Interrupt ***
WARNING: REDUNDANT POWER SUPPLY THERMAL BIT IS ASSERTED.