Caution

If you have redundant supervisor engines, you must install the same policy feature card on each
supervisor engine. The hardware on both the supervisor engines in a single chassis must be identical.

You must shut down the switch to install the policy feature card, even if you have redundant supervisor
engines.

Ensure that the policy feature card is securely seated before you install and tighten the cap nut and
the securing screws. If you use the screws to forcibly seat the policy feature card, the card might
warp.

You must use all the screws. The screws provide grounding between the policy feature card and the
supervisor engine. Failure to use and tighten all screws will invalidate the safety approval and pose
a fire and electrical hazard.

Use care not to damage the connectors on the supervisor engine. If you damage a connector, you
will have to return the supervisor engine to Cisco for repair.

Always use an ESD wrist strap when handling modules or coming into contact with internal
components.

Preparing the Supervisor Engine

To prepare Cisco Supervisor Engine 2T before you install or remove Policy Feature Card 4 or Policy Feature Card 4XL, perform
these steps:

Before You Begin

Always use an ESD wrist strap when handling modules or coming into contact with internal components.

Caution

Procedure

Step 1

Upload the current configuration to a server and save the running configuration on any modules running Cisco IOS software.

Performing this step saves time when bringing the module back online. You can recover the configuration by
downloading it from the server to the nonvolatile memory of the supervisor engine. For more information, refer
to Chapter 26, "Working with Configuration Files" in the

Catalyst 6500 Series Software Configuration Guide

on

Cisco.com.

Note

Step 2

Shut down the switch.

Step 3

Remove the supervisor engine from the chassis.
For removal instructions, see the

Catalyst 6500 Series Switch Module Installation Guide

on Cisco.com.

Step 4

Place the supervisor engine on an antistatic mat or foam.

What to Do Next

Install or remove the policy feature card.

4

Содержание PFC4

Страница 1: ...rts List 3 Required Tools 3 Installation Guidelines 3 Preparing the Supervisor Engine 4 Installing a Policy Feature Card 5 Verifying the Policy Feature Card Installation 8 Removing a Policy Feature Card 9 Applying the Label to the Supervisor Engine 10 Troubleshooting 10 Related Documentation 11 Obtaining Documentation and Submitting a Service Request 12 ...

Страница 2: ...odule when installing VS F6K PFC4XL For installation instructions see the Installation Note for the Supervisor Engine 2T DRAM Memory on Cisco com Note Safety Warnings Safety warnings appear throughout this publication in procedures that may harm you if you perform them incorrectly A warning symbol precedes each warning statement The warnings below are general warnings that are applicable to the en...

Страница 3: ... both the Policy Feature Card 4 kit and the Policy Feature Card 4XL kit One VS F6K PFC4 or VS F6K PFC4XL policy feature card One packet of labels One disposable grounding wrist strap One bag of mounting screws Required Tools These tools are required to perform the installation or removal of the Policy Feature Card 4 or Policy Feature Card 4XL Antistatic mat or foam pad to support the removed super...

Страница 4: ...handling modules or coming into contact with internal components Preparing the Supervisor Engine To prepare Cisco Supervisor Engine 2T before you install or remove Policy Feature Card 4 or Policy Feature Card 4XL perform these steps Before You Begin Always use an ESD wrist strap when handling modules or coming into contact with internal components Caution Procedure Step 1 Upload the current config...

Страница 5: ...delines on page 3 and Preparing the Supervisor Engine on page 4 Procedure Step 1 Remove the policy feature card from its antistatic bag Step 2 Insert the front edge of the policy feature card under the EMI gasket on the supervisor engine Figure 1 Inserting the PFC4XL Under the EMI Gasket Use care not to damage the connectors on the supervisor engine If you damage a connector you will have to retur...

Страница 6: ...connector you will have to return the supervisor engine to Cisco for repair Ensure that the policy feature card is securely seated before you install and tighten the cap nuts and the securing screws If you use the screws to forcibly seat the policy feature card the card might warp Step 4 Using your thumbs apply pressure at the locations shown in the following figure to ensure that the policy featu...

Страница 7: ...se a fire and electrical hazard Caution Use the supplied screws and cap nuts to secure the policy feature card to the supervisor engine Note Step 6 Install the supervisor engine in the switch chassis Refer to the Catalyst 6500 Series Switch Module Installation Guide for installation instructions What to Do Next 1 If you are installing a policy feature card on a redundant supervisor engine repeat t...

Страница 8: ... NAM 3 K9 SAL1530KNW3 6 48 CEF720 48 port 1000mb SFP WS X6848 SFP SAL1533MHD4 7 48 CEF720 48 port 10 100 1000mb Ethernet WS X6848 GE TX SAL1534N50G Mod MAC addresses Hw Fw Sw Status 1 1cdf 0f9b df26 to 1cdf 0f9b df39 1 0 12 2 50r SYL 15 1 2 SY2 Ok 3 2c54 2dc4 a0a5 to 2c54 2dc4 a0ac 1 5 12 2 50r SYS 15 1 2 SY2 Ok 4 2c54 2dc3 7499 to 2c54 2dc3 74a0 1 5 12 2 50r SYS 15 1 2 SY2 Ok 5 e8b7 4828 fc80 to ...

Страница 9: ...s on page 3 and Preparing the Supervisor Engine on page 4 Procedure Step 1 Remove the nine securing screws and two cap nuts and set them aside Use the supplied screws and cap nuts when securing a policy feature card to the supervisor engine Figure 5 Removing Securing Screws and Cap Nuts Use care not to damage the connectors on the supervisor engine If you damage a connector you will have to return...

Страница 10: ...feature card kit includes a label Apply the label to the upper left corner of the supervisor engine front panel Figure 7 Applying the Label Troubleshooting The following table provides troubleshooting tips that you can use if the policy feature card installation is not successful Table 1 Troubleshooting Solution Problem Remove the supervisor engine from the chassis and make sure that all the secur...

Страница 11: ...ote For additional information on Cisco Catalyst 6807 XL switches and command line interface CLI commands refer to the following publications located at http www cisco com go cat6800_docs Regulatory Compliance and Safety Information for the Catalyst 6880 X and 6807 XL Switches Cisco Catalyst 6807 XL Switch Hardware Installation Guide Release 15 1SY Supervisor Engine 2T Software Configuration Guide...

Страница 12: ...t Documentation which also lists all new and revised Cisco technical documentation at http www cisco com en US docs general whatsnew whatsnew html Subscribe to the What s New in Cisco Product Documentation as a Really Simple Syndication RSS feed and set content to be delivered directly to your desktop using a reader application The RSS feeds are a free service and Cisco currently supports RSS vers...

Страница 13: ...ntries To view a list of Cisco trademarks go to this URL http www cisco com go trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 1110R 2014 Cisco Systems Inc All rights reserved ...

Страница 14: ...coSystemsInternationalBV Amsterdam TheNetherlands CiscoSystems USA Pte Ltd Singapore Cisco Systems Inc San Jose CA 95134 1706 USA Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website at www cisco com go offices ...

Отзывы: