12-35
Cisco ONS 15327 User Documentation, R3.3
June 2002
Chapter 12 Maintenance
Power Down the ONS 15327
12.13 Power Down the ONS 15327
The following procedure describe how to power down a Cisco ONS 15327.
Warning
Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed
circuitry could constitute an energy hazard.
Caution
The following procedure is designed to minimize traffic outages when powering down nodes, but traffic
will be lost if you delete and recreate circuits that passed through a working node.
Note
Always use the supplied ESD wristband when working with the Cisco ONS 15327.
Procedure: Power Down the ONS 15327
Step 1
Identify the node that you want to power down. If no cards are installed, go to Step
. If cards are
installed, log into the node.
Step 2
In network view, verify that the node is not connected to a working network:
a.
If the node is part of a working network, log out of the node and remove the node from the network
and proceed to
b.
If the node is not connected to a working network and the current configurations are no longer
required, proceed to
Note
Current configurations will be saved if Steps
are skipped.
Step 3
In node view, click the
Circuits
tab and verify that no circuits are displayed. If no circuits are displayed,
. If circuits are displayed, delete all the circuits that originate or terminate in the node:
a.
Click the circuits that need to be deleted and click
Delete
.
b.
Click
Yes
.
Repeat until no circuits are displayed.
Step 4
In node view, click the
Provisioning > Protection
tabs and verify that no protection groups are
displayed. If no protection groups are displayed, proceed to Step 5. If protection groups are displayed,
delete the protection groups:
a.
Click the protection group that needs to be deleted and click
Delete
.
b.
Click
Yes
.
Repeat until no protection groups are displayed.
Step 5
In node view, click the
Provisioning > SONET DCC
tabs and verify that no SDCC terminations are
displayed. If no SDCC terminations are displayed, proceed to Step 6. If SDCC terminations are
displayed, delete the SDCC terminations:
a.
Click the SDCC Termination that needs to be deleted and click
Delete
.
b.
Click
Yes
.
Содержание ONS 15327
Страница 22: ...Contents xxii Cisco ONS 15327 User Documentation June 2002 I N D E X ...
Страница 30: ...Figures xxviii Cisco ONS 15327 User Documentation June 2002 ...
Страница 44: ...Procedures xlii Cisco ONS 15454 Installation and Operations Guide R3 2 June 2002 ...
Страница 82: ...1 32 Cisco ONS 15327 User Documentation R3 3 June 2002 Chapter 1 Hardware Installation Hardware Specifications ...
Страница 166: ...4 22 Cisco ONS 15327 User Documentation R3 3 June 2002 Chapter 4 IP Networking ONS 15327 Routing Table ...
Страница 254: ...7 22 Cisco ONS 15327 User Documentation R3 3 June 2002 Chapter 7 Card Provisioning Using Virtual Wires ...
Страница 408: ...13 26 Cisco ONS 15327 User Documentation R3 3 June 2002 Chapter 13 Card Reference E10 100 4 Card ...
Страница 540: ...Glossary GL 16 Cisco ONS 15327 User Documentation R3 3 June 2002 ...