1
NA
0.101
Xbar MAC-Address(es)
Serial-Num
---
--------------------------------------
----------
1
NA
JAF1225AGHJ
* this terminal session
switch#
Displaying Information for a Specific Supervisor or I/O Module
switch#
show module 1
Mod
Ports
Module-Type
Model
Status
---
-----
--------------------------------- ---------------- ------
1
48
1/10 Gbps Ethernet Module
N77-M348XP-23L
ok
Mod
Sw
Hw
---
--------------
------
1
7.3(0)DX(1)
0.701
Mod
MAC-Address(es)
Serial-Num
---
--------------------------------------
----------
1
50-06-ab-91-05-a0 to 50-06-ab-91-05-d3
JAE194108S6
Mod
Online Diag Status
---
------------------
1
Pass
Chassis Ejector Support: Enabled
Ejector Status:
Left ejector CLOSE, Right ejector CLOSE, Module HW does support
ejector based shutdown, Ejector policy enabled.
switch#
Displaying Information for a Specific Fabric Module
switch#
show module xbar 1
Xbar Ports
Module-Type
Model
Status
---
-----
----------------------------------- ------------------ ------
1
0
Fabric Module 1
N77-C7706-FAB-2
ok
Xbar Sw
Hw
---
--------------
------
1
NA
0.101
Xbar MAC-Address(es)
Serial-Num
---
--------------------------------------
----------
1
NA
JAE17260CCT
Chassis Ejector Support: Enabled
Ejector Status:
Top ejector OPEN, Bottom ejector OPEN, Module HW does not support ejector
based shutdown, Ejector policy disabled.
switch#
Purging the Module Configuration
You can clear the running configuration for an I/O slot that is not functioning by using the
purge module
command in EXEC mode.
Cisco Nexus 7718 Switch Site Preparation and Hardware Installation Guide
80
OL-30453-01
Managing the Switch
Purging the Module Configuration