• For information on a specific fabric module, use the
show module xbar slot_number
command to specify
a slot number.
For a description of the module status indicated by one of the above
show module
commands, see the following
table.
Description
I/O Module State
The hardware has electrical power. When the hardware is powered up, the software
begins booting.
powered up
The module has established connection with the supervisor and the module is
performing bootup diagnostics.
testing
The diagnostics have completed successfully and the configuration is being downloaded.
initializing
The switch detects a module failure upon initialization and automatically attempts to
power-cycle the module three times. After the third attempt, the module powers down.
failure
The switch is ready to be configured.
ok
The switch detects insufficient power for an I/O module to power up.
power-denied
This module is the active supervisor module and the switch is ready to be configured.
active
The HA switchover mechanism is enabled on the standby supervisor module.
HA-standby
Use the
show module
[
slot_number
] | [
xbar slot_number
]command in one of the following ways:
Description
Option
Displays information for all of the installed modules.
show module
Displays information for a supervisor or I/O module that you specify by its
slot number.
show module slot_number
Displays information for the fabric module that you specify by its slot
number.
show module xbar slot_number
Display information for all or specific modules.
Displaying Information for All Installed Modules
Displaying Information for a Specific Supervisor or I/O Module
Displaying Information for a Specific Fabric Module
switch#
show module
Mod
Ports
Module-Type
Model
Status
---
-----
----------------------------------- ------------------ ------
3
30
100 Gbps Ethernet Module
N77-F430CQ-36
ok
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
OL-30452-01.
66
Managing the Switch