Wait for the next retry attempt by the switch to bring up the supervisor-3E module.
•
Problem
The migration logging file is already present in the supervisor-2E module. The following syslog message
is displayed:
<Tue Apr 30 10:02:47 2019> WARNING!!! Migration logging file already exists in
Supervisor-2 (N77-SUP2E), continuing migration ...
Action to be performed
None. The
show logging onboard migration status
command is used to monitor the migration progress.
There is no impact on the migration process.
•
Problem
Unable to release the configuration lock that was set to prevent any configuration changes before switching
over to the supervisor-3E module. The following syslog message is displayed:
<Tue Apr 30 10:02:47 2019> ERROR!!! Failed to release config lock before switching over
to Supervisor-3 (N77-SUP3E), aborting migration …
Action to be performed
Use the
migrate sup kickstart <sup3-kickstart-image> system <sup3-system-image>
command again.
•
Problem
The switch cannot initiate migration logging due to internal errors. The following syslog message is
displayed:
<Tue Apr 30 10:02:47 2019> WARNING!!! Migration logging cannot be done due to Internal
Error, continuing migration ...
Action to be performed
None. The
show logging onboard migration status
command is used to monitor the migration progress.
There is no impact on the migration process.
•
Problem
The switch cannot initiate migration logging due to insufficient file permissions. The following syslog
message is displayed:
<Tue Apr 30 10:02:47 2019> WARNING!!! Migration logging cannot be done due to
file permission error, continuing migration ...
Action to be performed
None. The
show logging onboard migration status
command is used to monitor the migration progress.
This error message is displayed if the appropriate file permissions have not been provided.
•
Problem
The active supervisor-2E module is using the redundant secondary EOBC link instead of the primary
EOBC link. The following syslog message is displayed:
<Tue Apr 30 10:02:47 2019> ERROR!!! Active Supervisor-2 (N77-SUP2E) is using
Redundant EOBC link, this indicates some problem with Primary EOBC link,
aborting migration ...
Action to be performed
Replace the active supervisor-2E module with another supervisor-2E module.
Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
OL-30452-01.
106
Installing or Replacing Modules, Fan Trays, and Power Supplies
Troubleshooting