show running-config interface
show running-config interface
To display the running configuration for a specific port channel, use the
show running-config interface
command.
show running-config interface
[{
ethernet
slot/[QSFP-module/]port
|
fc
slot
/
port
|
loopback
number
|
mgmt
0
|
port-channel
channel-number
[
membership
] |
vethernet
veth-id
|
vlan
vlan-id
}] [
all
|
expand-port-profile
]
Syntax Description
Command Default
None
Command Modes
Any command mode
Command History
Examples
This example shows how to display the running configuration for port channel 10:
switch(config)#
show running-config interface port-channel 10
ethernet
slot/[QSFP-module/]port
(Optional) Displays the Ethernet interface slot number and port
number.The
slot
number is from 1 to 255. The
QSFP-module
number is
from 1 to 4. The
port
number is from 1 to 128.
Note
The
QSFP-module
number applies only to the QSFP+ Generic
Expansion Module (GEM).
fc
slot
/
port
(Optional) Displays the configuration information of the Fibre Channel
interface. The slot number is from 1 to 2 and the port number is from 1 to
48.
loopback
number
(Optional) Displays the number of the loopback interface. The range of
values is from 1 to 4096.
mgmt
0
(Optional) Displays the configuration information of the management
interface.
port-channel
channel-number
(Optional) Displays the number of the port-channel group. The range of
values is from 0 to 1023.
membership
Displays the membership of the specified port channel.
vethernet
veth-id
(Optional) Displays the configuration information of the virtual Ethernet
interface. The range is from 1 to 1048575.
vlan
vlan-id
(Optional) Displays the configuration information of the VLAN. The
range of values is from 1 to 4096.
all
(Optional) Displays configured and default information.
expand-port-profile
(Optional) Displays the configuration information of port profiles.
Release
Modification
6.0(2)N1(1)
Support for the QSFP+ GEM was added.
5.2(1)N1(1)
This command was introduced.
Содержание Nexus 5500 Series
Страница 4: ...4 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter ...
Страница 6: ...18 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter ...
Страница 36: ...130 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter C Commands connect ...
Страница 50: ...144 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter D Commands dvs name ...
Страница 124: ...1118 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter M Commands mvr type ...
Страница 126: ...1120 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter M Commands mvr vlan ...
Страница 131: ...1125 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter N Commands no switchport ...
Страница 132: ...1126 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter N Commands no switchport ...
Страница 158: ...1152 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter R Commands revision ...
Страница 438: ...1432 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter U Commands udld Ethernet ...