151
Cisco Nexus 5500 Series NX-OS Layer 2 Interfaces Command Reference
OL-27880-02
Chapter E Commands
erspan-id
erspan-id
To configure the flow ID for an Encapsulated Remote Switched Port Analyzer (ERSPAN)) session, use
the
erspan-id
command. To remove the flow ID, use the
no
form of this command.
erspan-id
flow_id
Syntax Description
Command Default
None
Command Modes
ERSPAN session configuration mode
Command History
Usage Guidelines
This command does not require a license.
Examples
This example shows how to configure the flow ID for an ERSPAN session:
switch#
configure terminal
switch(config)# monitor session 1 type erspan-source
switch(config-erspan-src)#
erspan-id 100
switch(config-erspan-src)#
Related Commands
flow_id
ERSPAN flow ID. The range is from 1 to 1023.
Release
Modification
5.2(1)N1(1)
This command was introduced.
Command
Description
ip dscp
Configures the DSCP value of the packets in the ERSPAN traffic.
ip ttl
Configures the IP time-to-live (TTL) value of the ERSPAN traffic.
mtu
Sets the maximum transmission unit (MTU) size for SPAN packet.
vrf
Configures the VRF for ERSPAN traffic forwarding.
monitor-session
Enters the monitor configuration mode for configuring an ERSPAN or
SPAN session for analyzing traffic between ports.
Содержание Nexus 5500 Series
Страница 4: ...4 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter ...
Страница 6: ...18 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter ...
Страница 36: ...130 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter C Commands connect ...
Страница 50: ...144 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter D Commands dvs name ...
Страница 124: ...1118 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter M Commands mvr type ...
Страница 126: ...1120 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter M Commands mvr vlan ...
Страница 131: ...1125 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter N Commands no switchport ...
Страница 132: ...1126 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter N Commands no switchport ...
Страница 158: ...1152 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter R Commands revision ...
Страница 438: ...1432 Cisco Nexus 5500 Series NX OS Layer 2 Interfaces Command Reference OL 27880 02 Chapter U Commands udld Ethernet ...