background image

If your Cisco Meraki device fails and the problem cannot be resolved by troubleshooting, contact support to address the issue. Once support determines that the
device is in a failed state, they can process an RMA and send out a replacement device free of charge. In most circumstances, the RMA will include a pre-paid
shipping label so the faulty equipment can be returned.

Additional warranty information can be found on:

https://meraki.cisco.com/support#process:warranty

Support and Additional Information

If issues are encountered with device installation or additional help is required,

contact Meraki Support

by logging in to

dashboard.meraki.com

and opening a

case by visiting the

Get Help

section.

• The equipment is intended for industrial or other commercial activities.

• The equipment is used in areas without exposure to harmful and dangerous production factors, unless otherwise

specified in the operational documentation and/or on the equipment labeling.

• The equipment is not for domestic use. The equipment is intended for operation without the constant presence of

maintenance personnel.

• The equipment is subject to installation and maintenance by specialists with the appropriate qualifications, sufficient

specialized knowledge, and skills.

• Rules and conditions for the sale of equipment are determined by the terms of contracts concluded by Cisco or

authorized Cisco partners with equipment buyers.

• Disposal of a technical device at the end of its service life should be carried out in accordance with the requirements

of all state regulations and laws.

• Do not throw in the device with household waste. The technical equipment is subject to storage and disposal in

accordance with the organization's disposal procedure.

• The equipment should be stored in its original packaging in a room protected from atmospheric precipitation. The

permissible temperature and humidity ranges during storage are specified in the Operation (Installation) Manual.

• Transportation of equipment should be carried out in the original packaging in covered vehicles by any means of

transport. The temperature and humidity during transportation must comply with the permissible established ranges
of temperature and humidity during storage (in the off state) specified in the Operation Manual (Installation).

For additional information on Meraki hardware and for other installation guides, please refer to

documentation.meraki.com

.

In order to initiate a hardware replacement for non-functioning hardware that is under warranty, you must have access to the original packaging the
hardware was shipped in. The original hardware packaging includes device serial number and order information, and may be required for return
shipping.

Meraki MX95/105 devices have been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. A
digital device that is marketed for use in a residential environment notwithstanding use in commercial, business and industrial environments.

9

Содержание Meraki MX105 Series

Страница 1: ...inistrators who demand both ease of deployment and a state of the art feature set The Meraki Dashboard allows for simple and easy deployment of the MX95 105 with minimal pre configuration in almost any location MX95 105 appliance provides the following features Four dedicated WAN uplinks two 10G SFP ports and two RJ45 2 5G mGig ports The LAN ports include four RJ45 1G ports and two SFP 10G ports D...

Страница 2: ...Party USB Modem Stateful Firewall Throughput 2 Gbps 3 Gbps Maximum VPN Throughput 800 Mbps 1 Gbps Security Throughput 1 Gbps 1 5 Gbps PoE Capabilities Yes 1x RJ45 Multigigabit Ethernet port WAN Yes 1x RJ45 Multigigabit Ethernet port WAN Recommended Use Case Mid to large enterprise locations with 500 users Mid to large enterprise locations with 750 users Physical Specifications MX95 MX105 SFP WAN I...

Страница 3: ... Internal 100 220V 50 60 Hz AC Modular 100 220V 50 60Hz AC 2 x 150WAC PSU Power Load idle max 42W 109W 53W 123W Operating Temperature 32 F to 104 F 0 C to 40 C 32 F to 104 F 0 C to 40 C Storage and Transportation Temperature 4 F 158 F 20 C 70 C 4 F 158 F 20 C 70 C Humidity 5 to 95 5 to 95 Accessories The Cisco Meraki MX95 105 models support pluggable optics for high speed backbone connections betw...

Страница 4: ...ditional functions are described below from left to right Function LED Status Meaning Power Solid orange Power is applied Rainbow colors Unit is attempting to contact the Cloud Flashing white Operation is in progress Solid white Fully operational USB connectivity Off During boot or USB link Solid orange Initial link Flashing orange Internet connectivity not complete Green USB connection detected H...

Страница 5: ...low Ventilation is from side to side not from front to back This MX security appliance requires a minimum of 10mm clearance between the venting holes and any obstruction Package Contents In addition to the MX device the following are provided MX95 MX105 Internal 2x 150W Power Supply Safety and Warnings Warning The system must be disconnected from all sources of power and the power cord removed fro...

Страница 6: ...e a new account 2 Find the network to which you plan to add your MX or create a new network 3 Add your MX to your network You will need your Meraki order number found on your invoice or the serial number of each MX which looks like Qxxx xxxx xxxx and is found on the bottom of the unit You will also need your Enterprise license key which you should have received via email 4 Go to the map floor plan...

Страница 7: ... information Setting up a DHCP IP Address By default all MX devices are configured to DHCP from upstream WAN ISP servers Simply plug the MX s WAN Internet port to your upstream circuit and wait a few minutes for the unit to negotiate a DHCP address Additional Settings Setting VLANs If your WAN uplink is on a trunk port choose VLAN tagging Use VLAN tagging and enter the appropriate value for VLAN I...

Страница 8: ...h your MX Reset the MX Factory reset the MX by holding the factory reset button for 5 seconds Try switching cables or testing your cable on another device Reference https documentation meraki com MX for additional information and troubleshooting tips If you are still experiencing hardware issues please contact Cisco Meraki support by logging in to dashboard and using the Help option near the top o...

Страница 9: ...ent buyers Disposal of a technical device at the end of its service life should be carried out in accordance with the requirements of all state regulations and laws Do not throw in the device with household waste The technical equipment is subject to storage and disposal in accordance with the organization s disposal procedure The equipment should be stored in its original packaging in a room prot...

Отзывы: