62
Figure 37 Connecting the Alarm Connector to the Switch
2.
Use a ratcheting torque flathead screwdriver to tighten the captive screws on the sides of the alarm connector.
Connecting Destination Ports
These section provide more information about connecting to the destination ports:
Connecting to 10/100 and 10/100/1000 Ports, page 62
Installing and Removing SFP Modules, page 64
Connecting to SFP Modules, page 68
Connecting to a Dual-Purpose Port, page 70
Connecting to 10/100 and 10/100/1000 Ports
The switch 10/100/1000 ports automatically configure themselves to operate at the speed of attached devices. If the
attached ports do not support autonegotiation, you can explicitly set the speed and duplex parameters. Connecting
devices that do not autonegotiate or that have their speed and duplex parameters manually set can reduce performance
or result in no linkage.
Warning:
Do not connect or disconnect cables to the ports while power is applied to the switch or any device on
the network because an electrical arc can occur. This could cause an explosion in hazardous location installations.
Be sure that power is removed from the switch and cannot be accidentally be turned on, or verify that the area is
nonhazardous before proceeding.
Statement 1070
1
Alarm connector upper captive screw
16TC
±12/24/48
0.5-3.0A
331215
1