![Cisco IE 2000 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/cisco/ie-2000/ie-2000_installation-manual_2609051060.webp)
60
Figure 34 Inserting Wires into the Alarm Connector (Alarm Input Circuit)
5.
Use a ratcheting torque flathead screwdriver to tighten the alarm connector captive screw (above the installed wire
leads) to 2 in-lb (0.23 N-m). (See
.)
Note:
Do not over-torque the power and alarm connectors’ captive screws. Do not exceed 2 inch-lbs (0.23 N-m) torque.
Figure 35 Securing the Alarm Connector Captive Screws
6.
Repeat the above steps to insert the input and output wires of one additional external alarm device into the alarm
connector.
shows the completed wiring for two external alarm devices. The first alarm device circuit is wired
as an alarm input circuit; the IN1 and REF connections complete the circuit. The second alarm device circuit is wired as
an alarm output circuit that works on a normally open contact basis; the NO and COM connections complete the circuit.
1
IN1 - External device connection 1
2
REF - External device connection 2
332225
1
2
332046
Содержание IE 2000
Страница 26: ...26 ...
Страница 77: ...77 Figure 45 Serial Number Location for the Cisco IE 2000 Switches 332705 781 00736 01 SN XXXNNNNXXXX ...
Страница 78: ...78 ...
Страница 94: ...94 ...