![Cisco D9859 Скачать руководство пользователя страница 315](http://html.mh-extra.com/html/cisco/d9859/d9859_installation-and-configuration-manual_67007315.webp)
OL-31980-01
291
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity ID
TXB ENC
Temper. Alarm
Set
Temperature
over Alarm
threshold
Cause: Room
temperature too
high, or air flow is
restricted.
Remedy: Check
the openings on
front and rear
panels for
blockage, assess
the room
temperature.
Lower the room
temperature or
improve air flow
to the device.
The transcoder
board encoder
temperature is
above safe
operating
range.
Major
33100
TXB ENC
Temper. Alarm
Clear
Temperature
normal
–
The transcoder
board encoder
temperature is
within the safe
operating
range.
Major
33100
ASI Out Status
Set
ASI Overflow.
Output Muted.
Reduce content.
Cause: Uplink
settings may have
changed since
setup of the unit.
Variable Bit
Rate/Statmuxed
streams may be in
use.
Remedy: Increase
the output rate,
drop unreferenced
content in DPM
Options, and/or
drop programs
not needed for
downstream
devices. Contact
your (uplink)
service provider to
verify the
expected bit rate
settings.
Current
transport rate
exceeds
configured rate
for ASI output.
Output has
been muted to
protect
downstream
devices.
Minor
34000
ASI Out Status
Clear
ASI Output
Restored
–
–
Minor
34000
Содержание D9859
Страница 6: ......
Страница 24: ......
Страница 32: ......
Страница 42: ......
Страница 342: ......
Страница 344: ......
Страница 378: ......
Страница 382: ...Appendix C Compliance 358 OL 31980 01 Declarationof Conformity ...
Страница 383: ...Declaration of Conformity OL 31980 01 359 ...
Страница 384: ......
Страница 389: ......