Configuring Transport Stream Information
OL-31980-01
189
If you want to configure an auxiliary PE, we highly recommend that you
perform the following:
-
From the
Enable Auto Map For Auxiliary PEs
drop-down list, choose
Yes
in
the ASI Outputs page.
-
Set PxA to
Map
.
-
Click
Resynchronize All
to ensure that the inputs and outputs are the same
.
4
Select the program entry you want to edit.
5
Click
Edit
. The DPM PE PID MAP window opens.
6
In the
Output Channel #
field, enter the output channel number you want to
map to the input channel (
Input Channel #
). This value is only used if the PE
Action
is set to
Map
. You can enter a range from 1 to 65535.
7
In the
Output PMT PID
field, enter the output PMT PID number you want to
map to the Input PMT PID.
8
In the
PE PID MAP
area, you can select an existing PID mapping entry you want
to modify or click
Add Row
to create a new entry.
9
The
Input Stream
indicates the input service that will be mapped by the current
entry. The
Input PID
displays the input PID (1 to 8190) that will be mapped by
the current entry. This is only used if the
Action
is set to Map.
10
From the
Action
drop-down list, choose the action to perform on the current
PID. The
Drop
action is always performed, but the
Map
option is only applied if
the PE
Action
is
Map
and the
Remapping Mode
is
Svc ID & PID
in the
DPM
General Settings
area.
Содержание D9859
Страница 6: ......
Страница 24: ......
Страница 32: ......
Страница 42: ......
Страница 342: ......
Страница 344: ......
Страница 378: ......
Страница 382: ...Appendix C Compliance 358 OL 31980 01 Declarationof Conformity ...
Страница 383: ...Declaration of Conformity OL 31980 01 359 ...
Страница 384: ......
Страница 389: ......