![Cisco Catalyst Blade 3032 Скачать руководство пользователя страница 754](http://html.mh-extra.com/html/cisco/catalyst-blade-3032/catalyst-blade-3032_software-configuration-manual_67665754.webp)
33-16
Cisco Catalyst Blade Switch 3130 and 3032 for Dell Software Configuration Guide
OL-13270-06
Chapter 33 Configuring SNMP
Configuring SNMP
Setting the CPU Threshold Notification Types and Values
Beginning in privileged EXEC mode, follow these steps to set the CPU threshold notification types and
values:
Setting the Agent Contact and Location Information
Beginning in privileged EXEC mode, follow these steps to set the system contact and location of the
SNMP agent so that these descriptions can be accessed through the configuration file:
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
process cpu threshold type
{
total
|
process
|
interrupt
}
rising
percentage
interval
seconds
[
falling
fall-percentage
interval
seconds
]
Set the CPU threshold notification types and values:
•
total
—set the notification type to total CPU utilization.
•
process
—set the notification type to CPU process utilization.
•
interrupt
—set the notification type to CPU interrupt utilization.
•
rising
percentage
—the percentage (1 to 100) of CPU resources
that, when exceeded for the configured interval, sends a CPU
threshold notification.
•
interval
seconds
—the duration of the CPU threshold violation in
seconds (5 to 86400) that, when met, sends a CPU threshold
notification.
•
falling
fall-percentage
—the percentage (1 to 100) of CPU
resources that, when usage falls below this level for the
configured interval, sends a CPU threshold notification.
This value must be equal to or less than the
rising
percentage
value. If not specified, the
falling
fall-percentage
value is the
same as the
rising
percentage
value.
Step 3
end
Return to privileged EXEC mode.
Step 4
show running-config
Verify your entries.
Step 5
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
snmp-server contact
text
Set the system contact string.
For example:
snmp-server contact Dial System Operator at beeper 21555
.
Step 3
snmp-server location
text
Set the system location string.
For example:
snmp-server location Building 3/Room 222
Step 4
end
Return to privileged EXEC mode.
Содержание Catalyst Blade 3032
Страница 46: ...Contents xlvi Cisco Catalyst Blade Switch 3130 and 3032 for Dell Software Configuration Guide OL 13270 06 ...
Страница 50: ...lii Cisco Catalyst Blade Switch 3130 and 3032 for Dell Software Configuration Guide OL 13270 06 Preface ...
Страница 1380: ...Index IN 54 Cisco Catalyst Switch Module 3110 and 3012 for IBM BladeCenter Software Configuration Guide OL 12189 06 ...