C9400-PWR-2100AC, C9400-PWR-3200AC, and
C9400-PWR-3200DC
Module
3.3 VDC
Fan Tray, Supervisor Module, Backplane
(Standby Output)
Power Supply Modes
Cisco Catalyst 9400 Series Switches offer redundant and combined configuration modes for power supplies.
The number of power supply modules installed and the system load determine the power level that the system
expects to draw from each power supply module, and consequently, the power supply mode that will be
suitable. To calculate, or estimate a system's power budget, and to determine power supply requirements for
a specific PoE configuration, use the
To configure a power supply mode, enter the
power redundancy-mode
command in global configuration
mode. If you do not configure a mode, the default mode is applicable.
Combined Mode
This is the default power supply mode.
The system operates on one to eight power supply modules. The power available to the system is the sum of
power outputs of all the power supply modules in the chassis. All available power supply modules are active,
share power, and can operate at up to 100 percent capacity.
When operating in combined mode, if any of the modules fail, all remaining operational power supply modules
increase their output. If the output power does not meet the system requirements and the
power supply autolc
shutdown
command is
disabled
, all the operational power supply modules may get overloaded and go into
overcurrent shutdown. All system power is then lost.
Caution
Redundant Mode
In a redundant configuration, a given power supply module can either be active, or in standby:
• An active power supply module is powered on, and provides output power. All the active modules in a
chassis always attempt to share the load.
• A standby power supply module is powered on, but asleep, and can switch to active when required. When
in standby mode, the power supply module’s OUTPUT LED is blinking green.
To ensure high availability, the system is designed to respond to failure as follows:
• If all the available power supply modules are active, the operational power supplies continue to share
current equally. Note that the load on the available power supplies would have increased.
• If standby power supply modules are available, the minimum number of power supply modules needed
to power the load switch to active.
When configuring a redundant mode, you have these options: an n+1 or an n+n redundant mode.
N+1 Redundant Mode
Cisco Catalyst 9400 Series Switches Hardware Installation Guide
23
Product Overview
Power Supply Modes
Содержание Catalyst 9400 Series
Страница 10: ...Cisco Catalyst 9400 Series Switches Hardware Installation Guide 4 Safety Warnings ...
Страница 52: ...Cisco Catalyst 9400 Series Switches Hardware Installation Guide 46 Standard Accessory Kit Contents ...
Страница 190: ...Cisco Catalyst 9400 Series Switches Hardware Installation Guide IN 4 INDEX ...
Страница 192: ......