Connector Specifications
Connecting to 1000BASE-T Devices
When you connect the ports to 1000BASE-T devices, such as servers, workstations, and routers, you
must use a four twisted-pair, Category 5, straight-through cable wired for 10BASE-T, 100BASE-TX, and
1000BASE-T.
Figure B-5
shows the straight-through cable schematics.
When you connect the ports to other devices, such as switches or repeaters, you must use a four
twisted-pair, Category 5, crossover cable.
Figure B-6
shows the crossover cable schematics.
Note
Be sure to use a four twisted-pair, Category 5 cable when connecting to a 1000BASE-T-compatible
device.
Note
Use a straight-through cable to connect two ports only when one port is designated with an X. Use a
crossover cable to connect two ports when both ports are designated with an X or when both ports do
not have an
X
.
Figure B-1
10/100/1000 Port Pinouts
SFP Module Ports
The blade switch uses SFP modules for fiber-optic ports. Refer to the blade switch release notes for a
list of supported SFP modules.
Figure B-2
Fiber-Optic SFP Module LC Connector
60915
2 3
1
4 5 6 7 8
Pin
Label
1
2
3
4
5
6
7
8
TP0+
TP0-
TP1+
TP2+
TP2-
TP1-
TP3+
TP3-
58476