![Cisco Catalyst 3040 Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/cisco/catalyst-3040/catalyst-3040_hardware-installation-manual_67603040.webp)
2-18
Cisco Catalyst Blade Switch 3040 for FSC Hardware Installation Guide
OL-10694-01
Chapter 2 Blade Switch Installation
Connecting to the 10/100/1000 Ports
Connecting to the 10/100/1000 Ports
The 10/100/1000 ports configure themselves to operate at the speed of attached devices. If the attached
ports do not support autonegotiation, you can explicitly set the speed and duplex parameters. Connecting
devices that do not autonegotiate or that have their speed and duplex parameters manually set can reduce
performance or result in no linkage.
To maximize performance, choose one of these methods for configuring the Ethernet ports:
•
Let the ports autonegotiate both speed and duplex.
•
Set the port speed and duplex parameters on both ends of the connection.
Follow these steps to connect to 10BASE-T, 100BASE-TX or 1000BASE-T devices:
Caution
To prevent electrostatic-discharge (ESD) damage, follow your normal board and component handling
procedures.
Step 1
When connecting to workstations, servers, routers, and Cisco IP Phones, connect a straight-through
cable to an RJ-45 connector on the front panel. (See
Figure 2-10
.) When connecting to switches or
repeaters, use a crossover cable. (See the
“Cable and Adapter Specifications” section on page B-3
for
cable-pinout descriptions.)
Figure 2-10
Connecting to an Ethernet Port
Note
When you connect to 1000BASE-T-compatible devices, be sure to use a twisted four-pair,
Category 5 cable.
Step 2
Connect the other end of the cable to an RJ-45 connector on the other device. The port LED turns on
when both the blade switch and the connected device have established link.
The port LED is amber while Spanning Tree Protocol (STP) discovers the topology and searches for
loops. This takes about 30 seconds, and then the port LED turns green. If the port LED does not turn on,
the device at the other end might not be turned on, or there might be a cable problem or a problem with
the adapter installed in the attached device. See
Chapter 3, “Troubleshooting,”
for solutions to cabling
problems.
190490
11x
12x
13x
14x
15x
16x
Console
11x
12x
13x
14x
15x
16x
CON
ID