Chapter 3 Troubleshooting
Diagnosing Problems
3-4
Catalyst 2900 Series XL Hardware Installation Guide
78-6461-03
Table 3-2
Common Problems and Their Solutions
Symptom
Possible Cause
Resolution
Poor Performance or
Excessive Errors.
Duplex autonegotiation mismatch.
Refer to the Catalyst 2900 Series
XL and Catalyst 3500 Series XL
Software Configuration Guide for
information on identifying
autonegotiation mismatches.
Cabling distance exceeded.
•
Port statistics show excessive frame
check sequence (FCS), late-collision,
or alignment errors.
•
For 100BASE-TX connections:
–
The distance between the port
and the attached device exceeds
328 feet (100 meters).
–
If the switch is attached to a
repeater, the total distance
between the two end stations
exceeds the 100BASE-T cabling
guidelines.
•
For 10BASE-T connections: The
distance between the port and the
attached device exceeds 328 feet
(100 meters).
•
Refer to the Catalyst 2900
Series XL and Catalyst 3500
Series XL Software
Configuration Guide for
information on displaying
port statistics.
•
Reduce the cable length to
within the recommended
distances.
Refer to your 100BASE-T
repeater documentation for
cabling guidelines.
•
Reduce the cable length to
within the recommended
distances.
Bad adapter in attached device.
•
Excessive errors found in port
statistics.
•
STP checking for possible loops.
•
Run adapter card diagnostic
utility.
•
Wait 30 seconds for LED to
turn green.